Literature DB >> 20865754

Ionic liquid-bonded polysiloxane as stationary phase for capillary gas chromatography.

Xiaojie Sun1, Caiying Wu, Jun Xing.   

Abstract

Ionic liquid (IL) stationary phase is especially suitable for separation of complex samples, owing to the "dual nature" of IL. In this study, a synthetic method of ionic liquid-bonded polysiloxane (PSOIL) as stationary phase of GC was proposed. Then, the PSOIL was used to prepare an 8  m capillary column by static method. The column efficiency was measured to be about 4000  plates/m (k=3.55, naphthalene) after the column had been conditioned at 210°C. The durability of PSOIL column was better than that of the mixed stationary phase of IL and OV-1. Moreover, the Abraham solvation parameter model was employed to characterize the PSOIL. The result revealed that the PSOIL had stronger dispersion force (l) than neat IL and stronger hydrogen bond basicity (a) than DB-1. That meant the PSOIL might offer good selectivity for both polar and non-polar analytes. The column exhibited unique selectivity for various organic substances, such as the homologous compounds of alkanes, esters, alcohols and aromatic compounds. It was also found that some aromatic positional isomers could be separated better on the PSOIL column than on the DB-1 column. Furthermore, the stationary phase was suitable for separation of high-boiling point compounds such as polycyclic aromatic hydrocarbons, phthalic esters, etc. All of these demonstrated that the PSOIL offered good selectivity and high separation efficiency for a wide range of analytes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20865754     DOI: 10.1002/jssc.201000030

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  3 in total

1.  Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity.

Authors:  Walter B Wilson; Lane C Sander; Jorge O Oña-Ruales; Stephanie G Mössner; Leonard M Sidisky; Milton L Lee; Stephen A Wise
Journal:  J Chromatogr A       Date:  2017-01-10       Impact factor: 4.759

2.  Polysiloxane ionic liquids as good solvents for β-cyclodextrin-polydimethylsiloxane polyrotaxane structures.

Authors:  Narcisa Marangoci; Rodinel Ardeleanu; Laura Ursu; Constanta Ibanescu; Maricel Danu; Mariana Pinteala; Bogdan C Simionescu
Journal:  Beilstein J Org Chem       Date:  2012-09-24       Impact factor: 2.883

3.  Detection of Polycyclic Aromatic Hydrocarbons in Water Samples by Annular Platform-Supported Ionic Liquid-Based Headspace Liquid-Phase Microextraction.

Authors:  Xiaojie Sun; Jie Tan; Haiyan Ding; Xiaojie Tan; Jun Xing; Lihong Xing; Yuxiu Zhai; Zhaoxin Li
Journal:  J Anal Methods Chem       Date:  2018-09-27       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.