Estimation of perfusion and arterial transit time in myocardium using free-breathing myocardial arterial spin labeling with navigator-echo.

Danny J J Wang1, Xiaoming Bi, Brian B Avants, Tongbai Meng, Sven Zuehlsdorff, John A Detre.   

Abstract

Arterial spin labeling (ASL) provides noninvasive measurement of tissue blood flow, but sensitivity to motion has limited its application to imaging of myocardial blood flow. Although different cardiac phases can be synchronized using electrocardiography triggering, breath holding is generally required to minimize effects of respiratory motion during ASL scanning, which may be challenging in clinical populations. Here a free-breathing myocardial ASL technique with the potential for reliable clinical application is presented, by combining ASL with a navigator-gated, electrocardiography-triggered TrueFISP readout sequence. Dynamic myocardial perfusion signals were measured at multiple delay times that allowed simultaneous fitting of myocardial blood flow and arterial transit time. With the assist of a nonrigid motion correction program, the estimated mean myocardial blood flow was 1.00 ± 0.55 mL/g/min with a mean transit time of ∼ 400 msec. The intraclass correlation coefficient of repeated scans was 0.89 with a mean within subject coefficient of variation of 22%. Perfusion response during mild to moderate stress was further measured. The capability for noninvasive, free-breathing assessment of myocardial blood flow using ASL may offer an alternative approach to first-pass perfusion MRI for clinical evaluation of patients with coronary artery disease.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20865753      PMCID: PMC2965813          DOI: 10.1002/mrm.22630

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

Review 1.  TrueFISP--technical considerations and cardiovascular applications.

Authors:  Friedrich Fuchs; Gerhard Laub; Kuni Othomo
Journal:  Eur J Radiol       Date:  2003-04       Impact factor: 3.528

2.  Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla.

Authors:  Jiongjiong Wang; David C Alsop; Lin Li; John Listerud; Julio B Gonzalez-At; Mitchell D Schnall; John A Detre
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

3.  Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling.

Authors:  Haosen Zhang; Steve M Shea; Vivian Park; Debiao Li; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  Magn Reson Med       Date:  2005-05       Impact factor: 4.668

4.  Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans.

Authors:  Li-Yueh Hsu; Kenneth L Rhoads; Jessica E Holly; Peter Kellman; Anthony H Aletras; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2006-03       Impact factor: 4.813

5.  Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): feasibility and noise analysis.

Authors:  Zungho Zun; Eric C Wong; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

6.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

Review 7.  Hibernating myocardium has reduced blood flow at rest that increases with low-dose dobutamine.

Authors:  S H Rahimtoola
Journal:  Circulation       Date:  1996-12-15       Impact factor: 29.690

8.  Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans.

Authors:  P Chareonthaitawee; P A Kaufmann; O Rimoldi; P G Camici
Journal:  Cardiovasc Res       Date:  2001-04       Impact factor: 10.787

9.  The optimal template effect in hippocampus studies of diseased populations.

Authors:  Brian B Avants; Paul Yushkevich; John Pluta; David Minkoff; Marc Korczykowski; John Detre; James C Gee
Journal:  Neuroimage       Date:  2009-10-08       Impact factor: 6.556

Review 10.  Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art.

Authors:  Bernhard L Gerber; Subha V Raman; Krishna Nayak; Frederick H Epstein; Pedro Ferreira; Leon Axel; Dara L Kraitchman
Journal:  J Cardiovasc Magn Reson       Date:  2008-04-28       Impact factor: 5.364

View more
  13 in total

1.  Spin-labeling magnetic resonance imaging detects increased myocardial blood flow after endothelial cell transplantation in the infarcted heart.

Authors:  Hualei Zhang; Hui Qiao; Rachel S Frank; Bin Huang; Kathleen J Propert; Susan Margulies; Victor A Ferrari; Jonathan A Epstein; Rong Zhou
Journal:  Circ Cardiovasc Imaging       Date:  2012-02-06       Impact factor: 7.792

Review 2.  Applications of arterial spin labeled MRI in the brain.

Authors:  John A Detre; Hengyi Rao; Danny J J Wang; Yu Fen Chen; Ze Wang
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

3.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

4.  Myocardial perfusion using arterial spin labeling CMR: promise and challenges.

Authors:  Frederick H Epstein; Craig H Meyer
Journal:  JACC Cardiovasc Imaging       Date:  2011-12

5.  Imaging Cell Therapy for Myocardial Regeneration.

Authors:  Hualei Zhang; Hui Qiao; Victor A Ferrari; Rong Zhou
Journal:  Curr Cardiovasc Imaging Rep       Date:  2011-11-25

6.  Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

Authors:  Yi Wang; Xingfeng Shao; Thomas Martin; Steen Moeller; Essa Yacoub; Danny J J Wang
Journal:  Magn Reson Med       Date:  2015-12-15       Impact factor: 4.668

7.  Myocardial arterial spin labeling perfusion imaging with improved sensitivity.

Authors:  Hung Phi Do; Terrence R Jao; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2014-01-27       Impact factor: 5.364

Review 8.  Myocardial arterial spin labeling.

Authors:  Frank Kober; Terrence Jao; Thomas Troalen; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-12       Impact factor: 5.364

9.  Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.

Authors:  Sebastian Berisha; Joyce Han; Mohammed Shahid; Yuchi Han; Walter R T Witschey
Journal:  PLoS One       Date:  2016-03-22       Impact factor: 3.240

10.  A look-locker acquisition scheme for quantitative myocardial perfusion imaging with FAIR arterial spin labeling in humans at 3 tesla.

Authors:  Graeme A Keith; Christopher T Rodgers; Michael A Chappell; Matthew D Robson
Journal:  Magn Reson Med       Date:  2016-09-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.