Literature DB >> 20863718

Bone presence between the central peg's radial fins of a partially cemented pegged all poly glenoid component suggest few radiolucencies.

Ryan M Arnold1, Robin R High, Kevin T Grosshans, Craig W Walker, Edward V Fehringer.   

Abstract

BACKGROUND: Cement penetration problems and/or cement-induced bone necrosis may contribute to glenoid component failures. An all polyethylene component was developed that promotes biologic fixation between radial fins of its central peg and utilizes minimal cement fixation for its peripheral pegs, but it has little published data. We hypothesized better bone presence between the radial fins would be associated with less overall radiolucencies. This study's purpose was to utilize computed tomography (CT) and plain films to assess for bone between the central peg's radial fins and to assess overall component radiolucencies.
MATERIALS AND METHODS: Thirty-five of 48 consecutively performed total shoulder arthroplasties (TSA) for primary glenohumeral osteoarthritis were in patients able to participate a minimum 2 years after surgery. All had reamed humeral head bone packed between radial fins of the central peg and minimal cement for the peripheral pegs. Thin cut (0.625 mm) CT scans, standardized plain films, Simple Shoulder Tests (SST), and Constant scores were obtained. A musculoskeletal radiologist calculated Yian CT scores, bone presence between fins on CT, and Lazarus radiolucency scores.
RESULTS: At a mean of 43 months, by CT: 1) better Yian scores correlated with more bone between fins, and 2) bone was present in 6/6 inter-fin compartments in 23/35 shoulders, averaging 4.5/6 overall. Mean Lazarus radiolucency score was 0.45. Mean SST and Constant scores were 10.3 and 81.3, respectively.
CONCLUSION: TSA utilizing autologous bone in inter-fin compartments of the central peg and minimal peripheral peg cement maintained bone presence a minimum 2 years post-op. More bone imparted fewer overall component radiolucencies.
Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20863718     DOI: 10.1016/j.jse.2010.05.025

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  12 in total

1.  One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers.

Authors:  Frederick A Matsen; Joseph P Iannotti; R Sean Churchill; Lieven De Wilde; T Bradley Edwards; Matthew C Evans; Edward V Fehringer; Gordon I Groh; James D Kelly; Christopher M Kilian; Giovanni Merolla; Tom R Norris; Giuseppe Porcellini; Edwin E Spencer; Anne Vidil; Michael A Wirth; Stacy M Russ; Moni Neradilek; Jeremy S Somerson
Journal:  Int Orthop       Date:  2018-12-03       Impact factor: 3.075

2.  Clinics in diagnostic imaging (167). Total shoulder arthroplasty glenoid component loosening with secondary rotator cuff failure.

Authors:  Tien Jin Tan; Ahmad Mohammad Aljefri; Marc Bruce Elliott; Savvas Nicolaou
Journal:  Singapore Med J       Date:  2016-04       Impact factor: 1.858

3.  The glenoid in total shoulder arthroplasty.

Authors:  Mark Schrumpf; Travis Maak; Sommer Hammoud; Edward V Craig
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

4.  Ream and run and total shoulder: patient and shoulder characteristics in five hundred forty-four concurrent cases.

Authors:  Frederick A Matsen; Anastasia Whitson; Sarah E Jackins; Moni B Neradilek; Winston J Warme; Jason E Hsu
Journal:  Int Orthop       Date:  2019-06-25       Impact factor: 3.075

5.  Clinical and radiographic outcomes of total shoulder arthroplasty with a partially cemented all-polyethylene pegged bone-ingrowth glenoid component: a systematic review.

Authors:  Michael-Alexander Malahias; Lazaros Kostretzis; Ioannis Gkiatas; Efstathios Chronopoulos; Emmanouil Brilakis; Emmanouil Antonogiannakis
Journal:  Shoulder Elbow       Date:  2020-07-27

6.  Total shoulder replacement using a bone ingrowth central peg polyethylene glenoid component: a prospective clinical and computed tomography study with short- to mid-term follow-up.

Authors:  Giovanni Merolla; Giovanni Ciaramella; Elisabetta Fabbri; Gilles Walch; Paolo Paladini; Giuseppe Porcellini
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

7.  Porous metals and alternate bearing surfaces in shoulder arthroplasty.

Authors:  Shannon R Carpenter; Ivan Urits; Anand M Murthi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

8.  CT scan evaluation of glenoid component fixation: a prospective study of 27 minimally cemented shoulder arthroplasties.

Authors:  A Vidil; Ph Valenti; F Guichoux; J H Barthas
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-09

9.  A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty.

Authors:  Thomas Gregory; Ulrich Hansen; Monica Khanna; Celine Mutchler; Saik Urien; Andrew A Amis; Bernard Augereau; Roger Emery
Journal:  Acta Orthop       Date:  2013-11-29       Impact factor: 3.717

10.  Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid.

Authors:  Dong Min Kim; Mohammed Aldeghaither; Fahad Alabdullatif; Myung Jin Shin; Erica Kholinne; Hyojune Kim; In-Ho Jeon; Kyoung-Hwan Koh
Journal:  BMC Musculoskelet Disord       Date:  2020-02-21       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.