Literature DB >> 20863543

A new algorithm for spatial impulse response of rectangular planar transducers.

Jiqi Cheng1, Jian-Yu Lu, Wei Lin, Yi-Xian Qin.   

Abstract

Previous solutions for spatial impulse responses of rectangular planar transducers require either approximations or complex geometrical considerations. This paper describes a new, simplified and exact solution using only trigonometric functions and simple set operations. This solution, which can be numerically implemented with a straightforward algorithm, is an exact implementation of the Rayleigh integral without any far field or paraxial approximation. Additionally, a nonlinear relationship was also established for spatial impulse responses from two field points which share the same projection point on the transducer surface plane. By incorporating this relationship in the algorithm, the computational efficiency of spatial impulse responses and continuous fields is improved about 20-folds and 14-folds, respectively. This algorithm has practical applications in designing l-D linear/phased arrays, 1.5-D arrays and 2-D arrays, as demonstrated through numerical simulations with array transducers. Experiments were also conducted to verify the new solution and results show that the algorithm is both accurate and efficient. The application of this method may include development of ultrasound imaging system for hard and soft tissue nondestructive assessment.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20863543      PMCID: PMC2991524          DOI: 10.1016/j.ultras.2010.08.007

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  2 in total

1.  High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings.

Authors:  Jian-Yu Lu; Jiqi Cheng; Jing Wang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-10       Impact factor: 2.725

2.  A new algorithm to calculate the transient near-field of ultrasonic phased arrays.

Authors:  L G Ullate; J L San Emeterio
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

  2 in total
  1 in total

1.  A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers.

Authors:  Cheng Zou; Zhenguo Sun; Dong Cai; Salman Muhammad; Wenzeng Zhang; Qiang Chen
Journal:  Sensors (Basel)       Date:  2016-11-08       Impact factor: 3.576

  1 in total