Literature DB >> 20863250

Targeting aerosolized drugs to the conducting airways using very large particles and extremely slow inhalations.

Kirby L Zeman1, Jihong Wu, William D Bennett.   

Abstract

BACKGROUND: The site of deposition in the respiratory tract for aerosolized, inhaled therapeutic drugs depends on both the particles' aerodynamic size and the patient's breathing pattern.
METHODS: In 21 healthy subjects with normal lung function, we evaluated an extremely slow inhalation of a large 9.5-μm MMAD particle aerosol (ESI-9) for its ability to enhance the delivery of radiolabeled particles ((99m)Tc-labeled sulfur colloid) to the conducting airways. The regional deposition of the large particles (modified Pari-Boy jet nebulizer), inhaled at the extremely low rate of 0.080 Lps for 10 sec, was compared to the deposition of 5-μm MMAD particles inhaled during cyclic resting tidal breathing (TVB-5-) (mean 0.44 L and 0.46 Lps). Gamma scintigraphy gave an estimate of conducting airway deposition (% CAD) as a fraction of all deposited particles by multiplying the percent of activity in both lungs immediately postdeposition relative to the total deposition (i.e., lungs + mouth + esophagus + stomach) times the percent of activity cleared from the lungs over 24 h.
RESULTS: % CAD for healthy subjects for the ESI-9 and TVB-5 maneuvers was 35% (±8%) and 27% (±11%), respectively, p = 0.004). The amount deposited within the oropharynx was 26% (±7%) and 37% (±11%), respectively, p < 0.001.
CONCLUSIONS: Higher therapeutic value of a medication delivered to the conducting airways where the primary defect is associated with many diseases, and with fewer losses to the extrathoracic surfaces, may be obtained by using an "extremely slow inhalation and large particle" routine when compared to a normal tidal volume breathing associated with typical nebulizers.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20863250     DOI: 10.1089/jamp.2008.0711

Source DB:  PubMed          Journal:  J Aerosol Med Pulm Drug Deliv        ISSN: 1941-2711            Impact factor:   2.849


  19 in total

Review 1.  Particle transport and deposition: basic physics of particle kinetics.

Authors:  Akira Tsuda; Frank S Henry; James P Butler
Journal:  Compr Physiol       Date:  2013-10       Impact factor: 9.090

Review 2.  Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs.

Authors:  Worth Longest; Benjamin Spence; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-07-09       Impact factor: 2.849

3.  Targeting aerosol deposition to and within the lung airways using excipient enhanced growth.

Authors:  Geng Tian; P Worth Longest; Xiang Li; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2013-01-03       Impact factor: 2.849

4.  Regional Ventilation Is the Main Determinant of Alveolar Deposition of Coarse Particles in the Supine Healthy Human Lung During Tidal Breathing.

Authors:  Rui Carlos Sá; Kirby L Zeman; William D Bennett; G Kim Prisk; Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2017-03-09       Impact factor: 2.849

Review 5.  Phage therapy for respiratory infections.

Authors:  Rachel Yoon Kyung Chang; Martin Wallin; Yu Lin; Sharon Sui Yee Leung; Hui Wang; Sandra Morales; Hak-Kim Chan
Journal:  Adv Drug Deliv Rev       Date:  2018-08-07       Impact factor: 15.470

6.  Inflammation induced by inhaled lipopolysaccharide depends on particle size in healthy volunteers.

Authors:  Virginie Doyen; Gabrielle Pilcer; Phong Huy Duc Dinh; Francis Corazza; Alfred Bernard; Pierre Bergmann; Nicolas Lefevre; Karim Amighi; Olivier Michel
Journal:  Br J Clin Pharmacol       Date:  2016-07-28       Impact factor: 4.335

7.  Duration of action of hypertonic saline on mucociliary clearance in the normal lung.

Authors:  W D Bennett; J Wu; F Fuller; J R Balcazar; K L Zeman; H Duckworth; K H Donn; T G O'Riordan; R C Boucher; S H Donaldson
Journal:  J Appl Physiol (1985)       Date:  2015-04-24

8.  Comparison of 133 xenon ventilation equilibrium scan (XV) and 99m technetium transmission (TT) scan for use in regional lung analysis by 2D gamma scintigraphy in healthy and cystic fibrosis lungs.

Authors:  Kirby L Zeman; Jihong Wu; Scott H Donaldson; William D Bennett
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2013-02-19       Impact factor: 2.849

9.  Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

Authors:  Jessica M Oakes; Miriam Scadeng; Ellen C Breen; G Kim Prisk; Chantal Darquenne
Journal:  Ann Biomed Eng       Date:  2013-01-25       Impact factor: 3.934

Review 10.  Aerosol deposition in the human lung in reduced gravity.

Authors:  Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2014-06       Impact factor: 2.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.