Literature DB >> 2086289

Quantitative determination of stress reduction by flow in composite restorations.

A J Feilzer1, A J De Gee, C L Davidson.   

Abstract

In this study, the reduction of the polymerization shrinkage stress by flow of four chemically-initiated composites was investigated in relation to the cavity configuration. In an experimental set-up simulating restorations bonded to cavity walls, the developing shrinkage stress accompanied by flow was recorded as a function of time for several configurations. For each configuration, theoretical shrinkage stress curves were also drawn, excluding stress reduction by flow. These data were obtained from Young's modulus determinations at the early setting stage and the corresponding polymerization shrinkage. By comparison of the theoretical stress with the experimentally determined stress, a measure for the ability to flow in the bonded situation could be obtained. It was found that the flow strongly depended on the type of composite and on the configuration of the cavity.

Mesh:

Substances:

Year:  1990        PMID: 2086289     DOI: 10.1016/0109-5641(90)90023-8

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  21 in total

1.  EFFECTS OF FILLER, INITIATOR AND CAVITY DESIGN FACTOR ON POLYMERIZATION STRESS DEVELOPED IN DENTAL COMPOSITES.

Authors:  J M Antonucci; A A Giuseppetti; J N R O'Donnell; G E Schumacher; D Skrtic
Journal:  Polymer Prepr       Date:  2008

2.  Silorane resin supports proliferation, differentiation, and mineralization of MLO-A5 bone cells in vitro and bone formation in vivo.

Authors:  J David Eick; Cielo Barragan-Adjemian; Jennifer Rosser; Jennifer R Melander; Vladimir Dusevich; Rachel A Weiler; Bradley D Miller; Kathleen V Kilway; Mark R Dallas; Lianxing Bi; Elisabet L Nalvarte; Lynda F Bonewald
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-01-25       Impact factor: 3.368

3.  Microleakage of resin-based sealants after Er:YAG laser conditioning.

Authors:  Laurence Lupi-Pégurier; Marie-France Bertrand; Olivier Genovese; Jean-Paul Rocca; Michèle Muller-Bolla
Journal:  Lasers Med Sci       Date:  2007-01-26       Impact factor: 3.161

4.  System compliance dictates the effect of composite filler content on polymerization shrinkage stress.

Authors:  Zhengzhi Wang; Martin Y M Chiang
Journal:  Dent Mater       Date:  2016-02-23       Impact factor: 5.304

5.  Role of filler and functional group conversion in the evolution of properties in polymeric dental restoratives.

Authors:  Parag K Shah; Jeffrey W Stansbury
Journal:  Dent Mater       Date:  2014-03-24       Impact factor: 5.304

Review 6.  Polymerization shrinkage assessment of dental resin composites: a literature review.

Authors:  Dalia Kaisarly; Moataz El Gezawi
Journal:  Odontology       Date:  2016-08-19       Impact factor: 2.634

7.  Influence of photoactivation method and mold for restoration on the Knoop hardness of resin composite restorations.

Authors:  William Cunha Brandt; Lais Regiane Silva-Concilio; Ana Christina Claro Neves; Eduardo Jose Carvalho de Souza-Junior; Mario Alexandre Coelho Sinhoreti
Journal:  Lasers Med Sci       Date:  2012-09-13       Impact factor: 3.161

8.  Polymerization stress evolution of a bulk-fill flowable composite under different compliances.

Authors:  Yongwen Guo; Forrest A Landis; Zhengzhi Wang; Ding Bai; Li Jiang; Martin Y M Chiang
Journal:  Dent Mater       Date:  2016-02-06       Impact factor: 5.304

9.  Simultaneous measurement of polymerization stress and curing kinetics for photo-polymerized composites with high filler contents.

Authors:  Zhengzhi Wang; Forrest A Landis; Anthony A M Giuseppetti; Sheng Lin-Gibson; Martin Y M Chiang
Journal:  Dent Mater       Date:  2014-11-21       Impact factor: 5.304

10.  Fabricating a hollow obturator with light-cured resin system.

Authors:  Aswini K Kar; H Parkash; L Garhnayak; B Chittaranjan
Journal:  J Indian Prosthodont Soc       Date:  2012-07-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.