Head positioning and risk of pneumocephalus, air embolism, and hemorrhage during subthalamic deep brain stimulation surgery.

Jules M Nazzaro1, Kelly E Lyons, Robyn A Honea, Matthew S Mayo, Galen Cook-Wiens, Amith Harsha, Jeffrey M Burns, Rajesh Pahwa.   

Abstract

PURPOSE: The objective of the present study was to evaluate the risk of pneumocephalus, venous air embolism (VAE), and intracranial hemorrhage in subthalamic nucleus (STN) deep brain stimulation (DBS) patients operated in the strict supine (head and body flat) position.
METHODS: This was a retrospective review of clinical records and brain imaging of patients who underwent STN DBS between January 2007 and June 2009 at the University of Kansas Medical Center.
RESULTS: A total of 61 patients underwent 114 lead implantations (53 staged bilateral and 8 unilateral). No case involved a transventricular route. Intracranial air volumes ranged from 0 to 7.02 cm³ (mean 0.98 ± 1.42 cm³). Pneumocephalus volumes were highly skewed with no air present after 44 (38.6%) lead implantations, >0 to 1 cm³ in 35 (30.7%), >2 to 3 cm³ in 17 (14.9%), and >3 cm³ (average 4.97 cm³) in 9 (7.9%). There was no incidence of clinically apparent VAE or symptomatic intracranial hemorrhage. There was no association between age, degree of atrophy, sagittal angle of surgical approach, number of microelectrode runs (MERs), distance of gyrus from inner skull bone at the entry point, or surgical side and pneumocephalus. However, the majority of lead implantations (100 leads; 88%) required only one MER and there were minimal measurable distances between entered gyrus and adjacent bone.
CONCLUSIONS: Our data suggest that strict supine positioning during STN DBS surgery results in minimal intracranial air and is not associated with VAE or symptomatic intracranial hemorrhage when the operative method described is used.

Entities:  

Mesh:

Year:  2010        PMID: 20862499     DOI: 10.1007/s00701-010-0776-5

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  6 in total

1.  Analysis of electrode deformations in deep brain stimulation surgery.

Authors:  Florent Lalys; Claire Haegelen; Tiziano D'albis; Pierre Jannin
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-19       Impact factor: 2.924

2.  Treatment of acute subdural hematoma.

Authors:  Carter Gerard; Katharina M Busl
Journal:  Curr Treat Options Neurol       Date:  2014-01       Impact factor: 3.598

3.  Pitfalls in precision stereotactic surgery.

Authors:  Ludvic Zrinzo
Journal:  Surg Neurol Int       Date:  2012-01-14

4.  The importance of testing deep brain stimulation lead impedances before final lead implantation.

Authors:  Jules M Nazzaro; Kelly E Lyons; Rajesh Pahwa; Larry W Ridings
Journal:  Surg Neurol Int       Date:  2011-09-27

5.  Effect of Cranial Window Diameter During Deep Brain Stimulation Surgery on Volume of Pneumocephalus.

Authors:  Justin Sharim; Patrick Pezeshkian; Antonio DeSalles; Nader Pouratian
Journal:  Neuromodulation       Date:  2015-07-29

6.  Early Deformation of Deep Brain Stimulation Electrodes Following Surgical Implantation: Intracranial, Brain, and Electrode Mechanics.

Authors:  Frédéric Chapelle; Lucie Manciet; Bruno Pereira; Anna Sontheimer; Jérôme Coste; Youssef El Ouadih; Ruxandra Cimpeanu; Dimitri Gouot; Yuri Lapusta; Béatrice Claise; Valérie Sautou; Yassine Bouattour; Ana Marques; Adrien Wohrer; Jean-Jacques Lemaire
Journal:  Front Bioeng Biotechnol       Date:  2021-06-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.