Literature DB >> 20862405

Volumetric determination of the amount of misfit in CAD/CAM and cast implant frameworks: a multicenter laboratory study.

Carl Drago1, Roxana L Saldarriaga, Daniel Domagala, Riad Almasri.   

Abstract

PURPOSE: The purposes of this study were (1) to evaluate the fit between implant frameworks and implants fabricated with two types of implant framework fabrication techniques: computer-aided design/computer-assisted machining (CAD/CAM) and conventional casting with the lost wax technique; and (2) to describe a digital measurement system consisting of tactile scanning and computer software programs that measured the volumetric differences between implant-supported frameworks and implant restorative platforms fabricated with these technologies.
MATERIALS AND METHODS: This laboratory study used acrylic resin models with five interforaminal implants. The models were scanned; implant-level impressions and verification indexes were then made to construct master casts. First, a cast gold alloy framework and a titanium milled bar fabricated with CAD/CAM technology were made to clarify the construction processes of each. After this pilot study was completed, five cast and five CAD/CAM frameworks were made at each of three dental schools (15 milled and 15 cast bars). Each framework was made on a master cast from individual impressions. The implant restorative interfaces of the frameworks were scanned, and the data were entered into a computer software program. The virtual representations of the frameworks were fit onto digitized scans of the implant restorative platforms and used for virtual one-screw tests on both sides of the arch. Volumetric differences between the implant restorative platforms of the implant-supported frameworks and the model implants were measured to determine the amount of misfit between the frameworks and the model implants.
RESULTS: Implant-supported frameworks made with the CAD/CAM technology fit significantly better onto the implants than the cast implant frameworks. There was a significant difference between the right and left one-screw tests; there were no significant differences among the three university sites.
CONCLUSIONS: The CAD/CAM frameworks featured in this study were significantly more accurate than cast frameworks made with the lost-wax technique.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20862405

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses.

Authors:  Fellwa AlRasheed; Khalid AlWazzan
Journal:  Saudi Dent J       Date:  2022-04-02

2.  Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report.

Authors:  Kwantae Noh; Woo-Jin Choi; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

3.  Effects of Different Surface Treatments on Bond Strength of Resin Cement to Machined Pure Titanium.

Authors:  Yang Cao; Yan-Yang Guo; Lei Chen; Jing Han; Hui Tong; Bao Zhang; Yu Zhang
Journal:  J Adhes Dent       Date:  2019       Impact factor: 2.359

4.  Oral Rehabilitation of Patients Sustaining Orofacial Injuries: The UPenn Initiative.

Authors:  Q Z Zhang; C Chen; M B Chang; R M Shanti; S B Cannady; B W O'Malley; S Shi; A D Le
Journal:  Adv Dent Res       Date:  2019-11

5.  Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

Authors:  Chui Ling Goo; Keson Beng Choon Tan
Journal:  Case Rep Dent       Date:  2017-03-15

6.  Biomechanical Behavior of an Implant System Using Polyether Ether Ketone Bar: Finite Element Analysis.

Authors:  Otávio Augusto Luitz Jaros; Geraldo Alberto Pinheiro De Carvalho; Aline Batista Gonçalves Franco; Simone Kreve; Paulo Augusto Batista Lopes; Sergio Cândido Dias
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

7.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20

8.  Effect of retention design of artificial teeth and implant-supported titanium CAD-CAM structures on fracture resistance.

Authors:  Kristin Ladetzki; Rocío Mateos-Palacios; Agustín Pascual-Moscardó; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2016-04-01
  8 in total