Literature DB >> 20861721

Biometric evaluation of keratoconic eyes with slit lamp-adapted optical coherence tomography.

Henning Aurich1, Duy Thoai Pham, Christopher Wirbelauer.   

Abstract

PURPOSE: To evaluate slit lamp-adapted optical coherence tomography for morphological imaging and morphometrical measurements in keratoconic eyes.
METHODS: Using slit lamp-adapted optical coherence tomography, we examined 32 eyes of 20 consecutive patients with keratoconus and described morphological attributes of the cornea. Furthermore, in a subgroup of 19 eyes, we measured morphometrical values of the cornea and compared these values with those of an age-matched control group of 19 normal eyes.
RESULTS: Of the 32 keratoconic eyes, 23 eyes had marked corneal thinning of less than 450 μm, 18 eyes had central stromal scarring, and 3 eyes had intrastromal cysts from acute hydrops formation. Central corneal thickness was measured as 374 ± 106 μm in the group of 19 keratoconic eyes, compared with 503 ± 127 μm in the control group (P < 0.05); anterior chamber depth was 3.6 ± 0.4 mm versus 3.1 ± 0.4 mm (P < 0.05); anterior curvature mean radius was 7.2 ± 1.2 mm versus 8.6 ± 1.0 mm (P < 0.05); posterior radius was 5.5 ± 0.7 mm versus 6.8 ± 0.7 mm (P < 0.05).
CONCLUSIONS: This study provides further validation that anterior segment optical coherence tomography is a reliable method to assess important parameters for diagnosis and therapeutic outcome control of patients with keratoconus. This method may be particularly useful as a safe and well-defined preoperative diagnostic tool before keratoplasty or corneal cross-linking.

Entities:  

Mesh:

Year:  2011        PMID: 20861721     DOI: 10.1097/ICO.0b013e3181e2ba61

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  3 in total

1.  Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt's striae: a contralateral eye study.

Authors:  Mohamad-Reza Sedaghat; Farshad Askarizadeh; Foroozan Narooie-Noori; Tahereh Rakhshandadi; Hadi Ostadi-Moghadam; Sattar Rajabi
Journal:  Clin Ophthalmol       Date:  2018-08-07

2.  Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes.

Authors:  Yasin Cınar; Abdullah Kürşat Cingü; Muhammed Sahin; Alparslan Sahin; Harun Yüksel; Fatih Mehmet Türkcü; Tuba Cınar; Ihsan Caça
Journal:  J Ophthalmol       Date:  2013-08-05       Impact factor: 1.909

3.  Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-Analysis.

Authors:  Hassan Hashemi; AbbasAli Yekta; Negareh Yazdani; Hadi Ostadimoghaddam; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2020-03-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.