Improvement of image quality of low radiation dose abdominal CT by increasing contrast enhancement.

Haruo Watanabe1, Masayuki Kanematsu, Toshiharu Miyoshi, Satoshi Goshima, Hiroshi Kondo, Noriyuki Moriyama, Kyongtae T Bae.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effects of noise index and contrast material dose on radiation dose, contrast enhancement, image noise, and image quality in abdominal CT. SUBJECTS AND METHODS: Contrast-enhanced abdominal CT with tube current modulation was performed on 195 patients. The patients were prospectively randomized into three groups of equal size (protocol A, noise index of 12 HU and 521 mg I/kg; protocol B, 15 HU and 521 mg I/kg; protocol C, 15 HU and 600 mg I/kg). Scanning was initiated 5 and 45 seconds after aortic enhancement reached 100 HU. Attenuation was measured in the aorta, portal vein, and liver. Transverse CT images were qualitatively graded for diagnostic acceptability and image noise. Arterial phase volume-rendered and multiplanar reformatted (MPR) images and portal venous phase MPR CT angiograms were qualitatively graded for depiction of vessels. Contrast enhancement, objective image noise, radiation dose, and qualitative grades were analyzed and compared among the three groups.
RESULTS: The contrast enhancement values of the aorta, portal vein, and liver were higher in protocol C than in protocols A and B (p < 0.05). Objective image noise was greater in protocols B and C than in protocol A (p < 0.05). The radiation dose in protocols B and C was 31-32% lower than in protocol A (p < 0.001). Depiction of vessels, diagnostic acceptability, and subjective image noise were comparable in protocols A and C.
CONCLUSION: Use of higher contrast enhancement can compensate for the degradation of image quality resulting from use of a low radiation dose for CT.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20858829     DOI: 10.2214/AJR.10.4456

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

1.  Improving abdomen tumor low-dose CT images using dictionary learning based patch processing and unsharp filtering.

Authors:  Yang Chen; Fei Yu; Limin Luo; Christine Toumoulin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

2.  Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Authors:  Chien-Ming Chen; Sung-Yu Chu; Ming-Yi Hsu; Ying-Lan Liao; Hui-Yu Tsai
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

3.  Computed tomography angiography of the carotid arteries at low kV settings: a prospective randomised trial assessing radiation dose and diagnostic confidence.

Authors:  Dietrich Beitzke; Florian Wolf; Gundula Edelhauser; Christina Plank; Rüdiger Schernthaner; Michael Weber; Richard Nolz; Johannes Lammer; Christian Loewe
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

4.  Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2011-06-07

5.  Diagnostic efficacy of single-pass abdominal multidetector-row CT: prospective evaluation of a low dose protocol.

Authors:  Luigi Camera; Immacolata Liccardo; Federica Romano; Raffaele Liuzzi; Antonio Rispo; Massimo Imbriaco; Anna Testa; Gaetano Luglio; Simona De Fronzo; Fabiana Castiglione; Luigi Bucci; Arturo Brunetti
Journal:  Br J Radiol       Date:  2016-11-09       Impact factor: 3.039

6.  Usefulness of dictionary learning-based processing for improving image quality of sub-millisievert low-dose chest CT: initial experience.

Authors:  Yoshinori Kanii; Yasutaka Ichikawa; Ryohei Nakayama; Motonori Nagata; Masaki Ishida; Kakuya Kitagawa; Shuichi Murashima; Hajime Sakuma
Journal:  Jpn J Radiol       Date:  2019-12-20       Impact factor: 2.374

Review 7.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

8.  Improving Low-dose Cardiac CT Images based on 3D Sparse Representation.

Authors:  Luyao Shi; Yining Hu; Yang Chen; Xindao Yin; Huazhong Shu; Limin Luo; Jean-Louis Coatrieux
Journal:  Sci Rep       Date:  2016-03-16       Impact factor: 4.379

Review 9.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.