Literature DB >> 20855861

Validation of 3D echocardiographic assessment of left ventricular volumes, mass, and ejection fraction in neonates and infants with congenital heart disease: a comparison study with cardiac MRI.

Mark K Friedberg1, Xioahong Su, Wayne Tworetzky, Brian D Soriano, Andrew J Powell, Gerald R Marx.   

Abstract

BACKGROUND: quantitative assessment and validation of left ventricular (LV) volumes and mass in neonates and infants with complex congenital heart disease (CHD) is important for clinical management but has not been undertaken. We compared matrix-array 3D echocardiography (3D echo) measurements of volumes, mass, and ejection fraction (EF) with those measured by cardiac MRI in young patients with CHD and small LVs because of either young age or LV hypoplasia. METHODS AND
RESULTS: thirty-five patients aged <4 years (median, 0.8 years) undergoing MRI were prospectively enrolled. Three-dimensional echo was acquired immediately after MRI, and volume, mass, and EF measurements, using summation of discs methodology, were compared with MRI. Three-dimensional echo end-diastolic volume (24.4±15.7 versus 24.8±46.4 mL; P=0.01; intraclass correlation coefficient [ICC], 0.96) and end-systolic volume (12.3±8.6 versus 9.6±6.8 mL; P<0.001; ICC, 0.90) correlated with MRI with small mean differences (-0.49 mL [P=0.6] and 2.7 mL [P=0.001], respectively). Three-dimensional echo EF was smaller than MRI by 9.3% (P<0.001), and 3D echo LV mass measurements were comparable to MRI (17.3±10.3 versus 17.6±12 g; P<0.77; ICC, 0.93), with a small mean difference (1.1 g; P=0.28). There was good intra- and interobserver reliability for all measurements.
CONCLUSIONS: in neonates and infants with CHD and small LVs (age appropriate or hypoplastic), matrix-array 3D echo measurements of mass and volumes compare well with MRI, providing an important modality for ventricular size and performance analysis in these patients, particularly in those with left-side heart obstructive lesions.

Entities:  

Mesh:

Year:  2010        PMID: 20855861     DOI: 10.1161/CIRCIMAGING.109.928663

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  24 in total

1.  Left ventricular mass and systolic function in children with chronic kidney disease-comparing echocardiography with cardiac magnetic resonance imaging.

Authors:  Raoul Arnold; Daniel Schwendinger; Sabine Jung; Martin Pohl; Bernd Jung; Julia Geiger; Charlotte Gimpel
Journal:  Pediatr Nephrol       Date:  2015-09-05       Impact factor: 3.714

Review 2.  Transthoracic echocardiography in the evaluation of pediatric pulmonary hypertension and ventricular dysfunction.

Authors:  Martin Koestenberger; Mark K Friedberg; Eirik Nestaas; Ina Michel-Behnke; Georg Hansmann
Journal:  Pulm Circ       Date:  2016-03       Impact factor: 3.017

3.  Left ventricle volume measured by cardiac CT in an infant with a small left ventricle: a new and accurate method in determining uni- or biventricular repair.

Authors:  Ho Jin Kim; Hyun Woo Goo; Sang-Hyub Park; Tae-Jin Yun
Journal:  Pediatr Radiol       Date:  2012-08-09

4.  Defining information needs in neonatal resuscitation with work domain analysis.

Authors:  Jelena Zestic; Penelope Sanderson; Jennifer Dawson; Helen Liley
Journal:  J Clin Monit Comput       Date:  2020-05-26       Impact factor: 2.502

Review 5.  Imaging of patients with congenital heart disease.

Authors:  Arno A W Roest; Albert de Roos
Journal:  Nat Rev Cardiol       Date:  2011-11-01       Impact factor: 32.419

6.  Ultrasound-Derived Three-Dimensional Printing in Congenital Heart Disease.

Authors:  Bennett P Samuel; Candida Pinto; Todd Pietila; Joseph J Vettukattil
Journal:  J Digit Imaging       Date:  2015-08       Impact factor: 4.056

7.  Multicenter study comparing shunt type in the norwood procedure for single-ventricle lesions: three-dimensional echocardiographic analysis.

Authors:  Gerald R Marx; Girish Shirali; Jami C Levine; Lin T Guey; James F Cnota; Jeanne M Baffa; William L Border; Steve Colan; Gregory Ensing; Mark K Friedberg; David J Goldberg; Salim F Idriss; J Blaine John; Wyman W Lai; Minmin Lu; Shaji C Menon; Richard G Ohye; David Saudek; Pierre C Wong; Gail D Pearson
Journal:  Circ Cardiovasc Imaging       Date:  2013-10-04       Impact factor: 7.792

8.  Ventricular pressure-volume loops obtained by 3D real-time echocardiography and mini pressure wire-a feasibility study.

Authors:  Ulrike Herberg; Eva Gatzweiler; Thomas Breuer; Johannes Breuer
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

9.  Comparison of stroke volumes assessed by three-dimensional echocardiography and transpulmonary thermodilution in a pediatric animal model.

Authors:  Katharina Linden; Dennis Ladage; Oliver Dewald; Eva Gatzweiler; Andrea Pieper; Matthias Seehase; Georg Daniel Duerr; Johannes Breuer; Ulrike Herberg
Journal:  J Clin Monit Comput       Date:  2016-02-17       Impact factor: 2.502

10.  Non-Invasive Imaging for Congenital Heart Disease: Recent Innovations in Transthoracic Echocardiography.

Authors:  Martin Koestenberger; Mark K Friedberg; William Ravekes; Eirik Nestaas; Georg Hansmann
Journal:  J Clin Exp Cardiolog       Date:  2012-01-22