Literature DB >> 20847118

Age-related differences in the elasticity of the human cornea.

Nathaniel E Knox Cartwright1, John R Tyrer, John Marshall.   

Abstract

PURPOSE: The goal of this study was to determine age-related variation in the elasticity of the human cornea using nondestructive means.
METHODS: Organ cultured human corneoscleral buttons were studied. Changes in strain were measured with a radial shearing speckle pattern interferometer after an increase in intraocular pressure from 15.0 to 15.5 mm Hg. Changes in central corneal displacement were calculated by integration, and a bulk corneal Young's modulus was derived by mathematical analysis.
RESULTS: Fifty corneas, including 17 pairs, were studied. Donors were aged between 24 and 102 years (mean, 73.1); 29 (58%) specimens were from male donors and 21 from female donors. Young's modulus of the cornea increased with age, with the line of best fit indicating an approximate doubling from 0.27 MPa at age 20 years (95% confidence interval, 0.22-0.31) to 0.52 (0.50-0.54) MPa at age 100 years (R² = 0.70).
CONCLUSIONS: The stiffness of the human cornea increases by a factor of approximately two between the ages of 20 and 100 years. This variation is relevant to the algorithms used to predict the response to incisional and ablative refractive surgery and will also affect the formulas used to calculate intraocular pressure by applanation.

Entities:  

Mesh:

Year:  2011        PMID: 20847118     DOI: 10.1167/iovs.09-4798

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  52 in total

1.  Corneal displacement during tonometry with a noncontact tonometer.

Authors:  Yoshiaki Kiuchi; Makoto Kaneko; Hideki Mochizuki; Joji Takenaka; Kenji Yamada; Junko Tanaka
Journal:  Jpn J Ophthalmol       Date:  2012-03-27       Impact factor: 2.447

2.  Correlation between biomechanical responses of posterior sclera and IOP elevations during micro intraocular volume change.

Authors:  Hugh J Morris; Junhua Tang; Benjamin Cruz Perez; Xueliang Pan; Richard T Hart; Paul A Weber; Jun Liu
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-01       Impact factor: 4.799

3.  24-hour IOP telemetry in the nonhuman primate: implant system performance and initial characterization of IOP at multiple timescales.

Authors:  J Crawford Downs; Claude F Burgoyne; William P Seigfreid; Juan F Reynaud; Nicholas G Strouthidis; Verney Sallee
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-21       Impact factor: 4.799

4.  Cyclic Pattern of Intraocular Pressure (IOP) and Transient IOP Fluctuations in Nonhuman Primates Measured with Continuous Wireless Telemetry.

Authors:  Jessica V Jasien; Daniel C Turner; Christopher A Girkin; J Crawford Downs
Journal:  Curr Eye Res       Date:  2019-06-19       Impact factor: 2.424

5.  The 2014 Bowman Lecture-Bowman's and Bruch's: a tale of two membranes during the laser revolution.

Authors:  J Marshall
Journal:  Eye (Lond)       Date:  2015-01       Impact factor: 3.775

6.  In vivo estimation of elastic wave parameters using phase-stabilized swept source optical coherence elastography.

Authors:  Ravi Kiran Manapuram; Salavat R Aglyamov; Floredes M Monediado; Maleeha Mashiatulla; Jiasong Li; Stanislav Y Emelianov; Kirill V Larin
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

7.  Anterior and posterior corneal stroma elasticity assessed using nanoindentation.

Authors:  Janice M Dias; Noël M Ziebarth
Journal:  Exp Eye Res       Date:  2013-06-22       Impact factor: 3.467

8.  Corneal Hydration Control during Ex Vivo Experimentation Using Poloxamers.

Authors:  Keyton Clayson; Thomas Sandwisch; Yanhui Ma; Elias Pavlatos; Xueliang Pan; Jun Liu
Journal:  Curr Eye Res       Date:  2019-09-18       Impact factor: 2.424

9.  Full-field displacement measurement of corneoscleral shells by combining multi-camera speckle interferometry with 3D shape reconstruction.

Authors:  Gianfranco Bianco; Luigi Bruno; Christopher A Girkin; Massimo A Fazio
Journal:  J Mech Behav Biomed Mater       Date:  2019-11-29

Review 10.  IOP telemetry in the nonhuman primate.

Authors:  J Crawford Downs
Journal:  Exp Eye Res       Date:  2015-07-26       Impact factor: 3.467

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.