Limited clinical utility of CT coronary angiography in a district hospital setting.

S M M Jenkins1, N Johnston, N M Hawkins, C-M Messow, J Shand, K J Hogg, H Eteiba, G McKillop, N E R Goodfield, A McConnachie, F G Dunn.   

Abstract

BACKGROUND: Studies have demonstrated considerable accuracy of multi-slice CT coronary angiography (MSCT-CA) in comparison to invasive coronary angiography (I-CA) for evaluating coronary artery disease (CAD). The extent to which published MSCT-CA accuracy parameters are transferable to routine practice beyond high-volume tertiary centres is unknown. AIM: To determine the accuracy of MSCT-CA for the detection of CAD in a Scottish district general hospital.
DESIGN: Prospective study of diagnostic accuracy.
METHOD: One hundred patients with suspected CAD recruited from two Glasgow hospitals underwent both MSCT-CA (Philips Brilliance 40 × 0.625 collimation, 50-200 ms temporal resolution) and I-CA. Studies were reported by independent, blinded radiologists and cardiologists and compared using the AHA 15-segment model.
RESULTS: Of 100 patients [55 male, 45 female, mean (SD) age 58.0 (10.7) years], 59 and 41% had low-intermediate and high pre-test probabilities of significant CAD, respectively. Mean (SD) heart rate during MSCT-CA was 68.8 (9.0) bpm. Fifty-seven per cent of patients had coronary artery calcification and 35% were obese. Patient prevalence of CAD was 38%. Per-patient sensitivity, specificity, positive and negative (NPV) predictive values for MSCT-CA were 92.1, 47.5, 52.2 and 90.6%, respectively. NPV was reduced to 75.0% in the high pre-test probability group. Specificity was compromised in patients with sub-optimally controlled heart rates, calcified arteries and elevated BMI.
CONCLUSION: Forty-Slice MSCT-CA has a high NPV for ruling out significant CAD when performed in a district hospital setting in patients with low-intermediate pre-test probability and minimal arterial calcification. Specificity is compromised by clinically appropriate strategies for dealing with unevaluable studies. Effective heart rate control during MSCT-CA is imperative. National guidelines should be utilized to govern patient selection and direct MSCT-CA reporter training to ensure quality control.

Entities:  

Mesh:

Year:  2010        PMID: 20847015     DOI: 10.1093/qjmed/hcq163

Source DB:  PubMed          Journal:  QJM        ISSN: 1460-2393


  2 in total

1.  Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

Authors:  Sabine Schueler; Stefan Walther; Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

Review 2.  Use of 3x2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies.

Authors:  Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  BMJ       Date:  2012-10-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.