Literature DB >> 20846850

Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer.

Jing Cai1, Jinbo Yue, Robert McLawhorn, Wensha Yang, Krishni Wijesooriya, Neal E Dunlap, Ke Sheng, Fang-Fang Yin, Stanley H Benedict.   

Abstract

We conducted a planning study to compare Varian's RapidArc (RA) and helical TomoTherapy (HT) for the treatment of pancreatic cancer. Three intensity-modulated radiotherapy (IMRT) plans were generated for 8 patients with pancreatic cancer: one using HT with 6-MV beam (Plan_(HT6)), one using single-arc RA with 6-MV beam (Plan_(RA6)), and one using single-arc RA with 15-MV beam (Plan_(RA15)). Dosimetric indices including high/low conformality index (CI(100%)/CI(50%)), heterogeneity index (HI), monitor units (MUs), and doses to organs at risk (OARs) were compared. The mean CI(100%) was statistically equivalent with respect to the 2 treatment techniques, as well as beam energy (0.99, 1.01, and 1.02 for Plan_(HT6), Plan_(RA6), and Plan_(RA156,) respectively). The CI(50%) and HI were improved in both RA plans over the HT plan. The RA plans significantly reduced MU (MU(RA6) = 697, MU(RA15) = 548) compared with HT (MU(HT6) = 6177, p = 0.008 in both cases). The mean maximum cord dose was decreased from 29.6 Gy in Plan_(HT6) to 21.6 Gy (p = 0.05) in Plan_(RA6) and 21.7 Gy (p = 0.04) in Plan_(RA15). The mean bowel dose decreased from 17.2 Gy in Plan_(HT6) to 15.2 Gy (p = 0.03) in Plan_(RA6) and 15.0 Gy (p = 0.03) Plan_(RA15). The mean liver dose decreased from 8.4 Gy in Plan_(HT6) to 6.3 Gy (p = 0.04) in Plan_(RA6) and 6.2 Gy in Plan_(RA15). Variations of the mean dose to the duodenum, kidneys, and stomach were statistically insignificant. RA and HT can both deliver conformal dose distributions to target volumes while limiting the dose to surrounding OARs in the treatment of pancreatic cancer. Dosimetric advantages might be gained by using RA over HT by reducing the dose to OARs and total MUs used for treatment.
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20846850     DOI: 10.1016/j.meddos.2010.07.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: a dosimetric analysis.

Authors:  Rachit Kumar; Aaron T Wild; Mark A Ziegler; Ted K Hooker; Samson D Dah; Phuoc T Tran; Jun Kang; Koren Smith; Jing Zeng; Timothy M Pawlik; Erik Tryggestad; Eric Ford; Joseph M Herman
Journal:  Med Dosim       Date:  2013-03-27       Impact factor: 1.482

2.  Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT?

Authors:  Gregory T Betzel; Byong Yong Yi; Ying Niu; Cedric X Yu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

3.  Optimal tumor coverage with different beam energies by IMRT, VMAT and TOMO: Effects on patients with proximal gastric cancer.

Authors:  Sheng-Fang Huang; Jang-Chun Lin; An-Cheng Shiau; Yun-Chih Chen; Ming-Hsien Li; Jo-Ting Tsai; Wei-Hsiu Liu
Journal:  Medicine (Baltimore)       Date:  2020-11-20       Impact factor: 1.817

  3 in total