Literature DB >> 20844336

Evaluation of an MR-compatible blood sampler for PET.

J Breuer1, R Grazioso, N Zhang, M Schmand, K Wienhard.   

Abstract

The integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) is an upcoming hybrid imaging technique. Prototype scanners for pre-clinical and clinical research have been built and tested. However, the potential of the PET part can be better exploited if the arterial input function (AIF) of the administered tracer is known. This work presents a dedicated MR-compatible blood sampling system for precise measurement of the AIF in an MR-PET study. The device basically consists of an LSO/APD-detector assembly which performs a coincidence measurement of the annihilation photons resulting from positron decays. During the measurement, arterial blood is drawn continuously from an artery and lead through the detector unit. Besides successful tests of the MR compatibility and the detector performance, measurements of the AIF of rats have been carried out. The results show that the developed blood sampling system is a practical and reliable tool for measuring the AIF in MR-PET studies.

Entities:  

Mesh:

Year:  2010        PMID: 20844336     DOI: 10.1088/0031-9155/55/19/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  A CZT-based blood counter for quantitative molecular imaging.

Authors:  Romain Espagnet; Andrea Frezza; Jean-Pierre Martin; Louis-André Hamel; Laëtitia Lechippey; Jean-Mathieu Beauregard; Philippe Després
Journal:  EJNMMI Phys       Date:  2017-06-02

2.  Explicit measurement of multi-tracer arterial input function for PET imaging using blood sampling spectroscopy.

Authors:  Carlos Velasco; Adriana Mota-Cobián; Jesús Mateo; Samuel España
Journal:  EJNMMI Phys       Date:  2020-02-06

3.  Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy.

Authors:  Carlos Velasco; Adriana Mota-Cobián; Jesús Mateo; Samuel España
Journal:  EJNMMI Phys       Date:  2019-12-16

4.  Development and performance test of an online blood sampling system for determination of the arterial input function in rats.

Authors:  Friedrich Roehrbacher; Jens P Bankstahl; Marion Bankstahl; Thomas Wanek; Johann Stanek; Michael Sauberer; Julia Muellauer; Thales Schroettner; Oliver Langer; Claudia Kuntner
Journal:  EJNMMI Phys       Date:  2015-01-14