Literature DB >> 20844170

Arthroscopic repair of circumferential lesions of the glenoid labrum: surgical technique.

John M Tokish1, Colleen M McBratney, Daniel J Solomon, Lance Leclere, Christopher B Dewing, Matthew T Provencher.   

Abstract

BACKGROUND: Symptomatic pan-labral or circumferential (360°) tears of the glenohumeral labrum are an uncommon injury. The purpose of the present study was to report the results of surgical treatment of circumferential lesions of the glenoid labrum with use of validated outcome instruments.
METHODS: From July 2003 to May 2006, forty-one shoulders in thirty-nine patients (thirty-four men and five women) with a mean age of 25.1 years were prospectively enrolled in a multicenter study and were managed for a circumferential (360°) lesion of the glenoid labrum. All patients had a primary diagnosis of pain and recurrent shoulder instability, and all underwent arthroscopic repair of the circumferential labral tear with a mean of 7.1 suture anchors. The outcomes for thirty-nine of the forty-one shoulders were assessed after a mean duration of follow-up of 31.8 months on the basis of the rating of pain and instability on a scale of 0 to 10, a physical examination, and three outcome instruments (the Single Assessment Numeric Evaluation score, the modified American Shoulder and Elbow Surgeons score, and the Short Form-12 score).
RESULTS: Significant improvement was noted in terms of the mean pain score (from 4.3 to 1.1), the mean instability score (from 7.3 to 0.2), the mean modified American Shoulder and Elbow Surgeons score (from 55.5 to 89.6), the mean Short Form-12 score (from 75.7 to 90.0), and the mean Single Assessment Numeric Evaluation score (from 36.7 to 88.5). Six shoulders required revision surgery because of recurrent instability (two), recalcitrant biceps tendinitis (two), or postoperative tightness (two). All patients returned to their preinjury activity level.
CONCLUSIONS: Pan-labral or circumferential lesions are an uncommon yet extensive injury of the glenohumeral joint that may result in recurrent instability and pain. The present study demonstrates that arthroscopic capsulolabral repair with suture anchor fixation can restore the stability of the glenohumeral joint and can provide a reliable improvement in subjective and objective outcome measures.

Entities:  

Mesh:

Year:  2010        PMID: 20844170     DOI: 10.2106/JBJS.J.00234

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

Review 1.  Arthroscopic stabilisation for shoulder instability.

Authors:  Konstantinos Fountzoulas; Syed Hassan; Al-Achraf Khoriati; Chu-Hao Chiang; Nicholas Little; Vipul Patel
Journal:  J Clin Orthop Trauma       Date:  2019-07-17

2.  Relationship between the extent of labral lesions and the frequency of glenohumeral dislocation in shoulder instability.

Authors:  Doo-Sup Kim; Chang-Ho Yi; Ki-Yeon Kwon; Jin-Rok Oh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-15       Impact factor: 4.342

3.  Clinical and morphologic factors associated with suture anchor refixation of labral tears in the hip.

Authors:  John A Ruder; Erin Magennis; Anil S Ranawat; Bryan T Kelly
Journal:  HSS J       Date:  2013-12-03

4.  Arthroscopic Repair of a Circumferential 360° Labral Tear.

Authors:  Allison J Rao; Gregory L Cvetanovich; William A Zuke; Quentin Low; Brian Forsythe
Journal:  Arthrosc Tech       Date:  2017-07-31

5.  A 360° Labral Repair Using Two Portals and a Percutaneous Cannula.

Authors:  James Gwosdz; Moyukh Chakrabarti; Alexander Rosinski; Patrick J McGahan; James L Chen
Journal:  Arthrosc Tech       Date:  2019-07-17

6.  Triple labrum tears repaired with the JuggerKnot™ soft anchor: Technique and results.

Authors:  Vivek Agrawal; William S Pietrzak
Journal:  Int J Shoulder Surg       Date:  2015 Jul-Sep

7.  Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures.

Authors:  Santos Moros Marco; José Luis Ávila Lafuente; Miguel Angel Ruiz Ibán; Jorge Diaz Heredia
Journal:  Open Orthop J       Date:  2017-08-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.