Literature DB >> 20841411

The accuracy of the anesthetic conserving device (AnaConDa©) as an alternative to the classical vaporizer in anesthesia.

Marina Soro1, Rafael Badenes, Maria Luisa Garcia-Perez, Lucia Gallego-Ligorit, Francisco J Martí, Gerardo Aguilar, F Javier Belda.   

Abstract

BACKGROUND: The Anesthetic Conserving Device--AnaConDa® (ACD)--has been compared with a conventional vaporizer. However, the accuracy of the administered concentration of volatile anesthetics was not examined. In the present study we measured the accuracy of the ACD when used as a portable vaporizer.
METHODS: This prospective study included 30 ASA I-III patients scheduled for elective surgery under general anesthesia. The patients were randomly organized into 3 groups of 10 patients per group. In each group, the sevoflurane infusion rate was adjusted to deliver 1.0 vol%, 1.5 vol%, and 2.0 vol% alveolar concentration. Hemodynamic data, bispectral index, and end-tidal sevoflurane concentrations were recorded every 2 minutes.
RESULTS: We analyzed 801 data points from 30 patients. The mean difference between the end-tidal sevoflurane concentration and the target concentration was -11.0 ± 9.3% of the target when the target was 1.0 vol%, -5.4 ± 6.4% when the target was 1.5 vol%, and -4.0 ± 7.4% when the target was 2.0 vol%. No significant differences were found in the error at the different target concentrations.
CONCLUSIONS: We found that the ACD may be a valid alternative to the conventional vaporizer. The ACD is very simple to use, delivery rate needs to be adjusted only once per hour, and the anesthetic savings are independent of the circuit characteristics and fresh gas flow rate.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20841411     DOI: 10.1213/ANE.0b013e3181f4db38

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  3 in total

1.  Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents.

Authors:  Krista Bigiarelli; Luke E Schepers; Arvin H Soepriatna; Dave FitzMiller; Craig J Goergen
Journal:  J Vis Exp       Date:  2020-07-09       Impact factor: 1.355

2.  Use of a Low-flow Digital Anesthesia System for Mice and Rats.

Authors:  Amelia R Adelsperger; Krista J Bigiarelli-Nogas; Irina Toore; Craig J Goergen
Journal:  J Vis Exp       Date:  2016-09-07       Impact factor: 1.355

3.  Sedation with sevoflurane in postoperative cardiac surgery: influence on troponin T and creatinine values.

Authors:  J M Marcos-Vidal; R González; C Garcia; C Soria; M Galiana; B De Prada
Journal:  Heart Lung Vessel       Date:  2014
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.