Literature DB >> 20839165

[Reference values in abdominal ultrasound - liver and liver vessels].

M Sienz1, A Ignee, Christoph F Dietrich.   

Abstract

OBJECTIVE: Reference values for B-mode abdominal ultrasound are being controversially discussed due to the limited data in the literature. A systematic survey of data published so far is presented for liver and hepatic vessels.
METHODS: A literature search for reference values in the abdomen from 1970 to 2010 in healthy subjects 18 years of age and older was carried out. In accord with the determination of reference intervals for laboratory values, reference values are generally determined with the aid of 95 % reference intervals and the associated 90 % confidence intervals. Evaluated parameters were the size and volume of the liver, the portal vein diameter and cross-section and the diameters of the hepatic veins.
RESULTS: Liver size is usually determined by its longitudinal diameter in the midclavicular line. Although not sufficiently evaluated, < 16 cm can be used as a reference value. Numerous methods, which are not comparable, have been described for the determination of liver volume. For the portal vein diameter, refererence intervals could be deduced from 6 studies. Data from 4 studies on the liver veins differ depending on the exact localisation of measurement. DISCUSSION: Normal values are helpful in delineating numerous pathological changes in the respective organs. Unfortunately, data are scarce and the examination technique, so far, has not been standardised sufficiently to compare data. A multicentre trial is required to standardise examination techniques and improve the quality of the results. © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Year:  2010        PMID: 20839165     DOI: 10.1055/s-0029-1245566

Source DB:  PubMed          Journal:  Z Gastroenterol        ISSN: 0044-2771            Impact factor:   2.000


  6 in total

Review 1.  Fortuitously discovered liver lesions.

Authors:  Christoph F Dietrich; Malay Sharma; Robert N Gibson; Dagmar Schreiber-Dietrich; Christian Jenssen
Journal:  World J Gastroenterol       Date:  2013-06-07       Impact factor: 5.742

2.  Evaluation of a novel tomographic ultrasound device for abdominal examinations.

Authors:  Valentin Blank; Johannes Wiegand; Volker Keim; Thomas Karlas
Journal:  PLoS One       Date:  2019-06-26       Impact factor: 3.240

3.  Ultrasonographic assessment of normal jugular veins in Standardbred horses.

Authors:  Maria Pia Pasolini; Giuseppe Spinella; Chiara Del Prete; Simona Valentini; Pierpaolo Coluccia; Luigi Auletta; Michele Greco; Leonardo Meomartino
Journal:  BMC Vet Res       Date:  2019-10-16       Impact factor: 2.741

4.  Ultrasonographic Measurements of the Liver, Gallbladder Wall Thickness, Inferior Vena Cava, Portal Vein and Pancreas in an Urban Region, Malaysia.

Authors:  Abdul Sattar Arif Khammas; Rozi Mahmud
Journal:  J Med Ultrasound       Date:  2020-10-01

5.  A clinical and molecular epidemiological survey of hepatitis C in Blantyre, Malawi, suggests a historic mechanism of transmission.

Authors:  Alexander J Stockdale; Benno Kreuels; Isaac T Shawa; James E Meiring; Deus Thindwa; Niza M Silungwe; Karen Chetcuti; Elizabeth Joekes; Maurice Mbewe; Blessings Mbale; Pratiksha Patel; Rabson Kachala; Priyanka D Patel; Jane Malewa; Peter Finch; Chris Davis; Rajiv Shah; Lily Tong; Ana da Silva Filipe; Emma C Thomson; Anna Maria Geretti; Melita A Gordon
Journal:  J Viral Hepat       Date:  2022-02-09       Impact factor: 3.517

6.  First-year medical students use of ultrasound or physical examination to diagnose hepatomegaly and ascites: a randomized controlled trial.

Authors:  Samantha Arora; Angela C Cheung; Usman Tarique; Arnav Agarwal; Mohammed Firdouse; Jonathan Ailon
Journal:  J Ultrasound       Date:  2017-08-19