We introduce a simple micro-fluidic device containing an actuated flexible membrane, which allows the viscoelastic characterization of cells in small volumes of suspension by loading them in compression and observing the cell deformation in time. From this experiment, we can determine the characteristic time constant of recovery of the cell. To validate the device, two cell types known to have different cytoskeletal structures, 3T3 fibroblasts and HL60 cells, are tested. They show a substantially different response in the device and can be clearly distinguished on the basis of the measured characteristic recovery time constant. Also, the effect of breaking down the actin network, a main mechanical component of the cytoskeleton, by a treatment with Cytochalasin D, results in a substantial increase of the measured characteristic recovery time constant. Experimental variations in loading force, loading time, and surface treatment of the device also influence the measured characteristic recovery time constant significantly. The device can therefore be used to distinguish between cells with different mechanical structure in a quantitative way, and makes it possible to study changes in the mechanical response due to cell treatments, changes in the cell's micro-environment, and mechanical loading conditions.

Entities:  

Mesh:

Year:  2011        PMID: 20838903      PMCID: PMC3028074          DOI: 10.1007/s10544-010-9468-4

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  27 in total

1.  Monolithic microfabricated valves and pumps by multilayer soft lithography.

Authors:  M A Unger; H P Chou; T Thorsen; A Scherer; S R Quake
Journal:  Science       Date:  2000-04-07       Impact factor: 47.728

2.  Mechanical properties of cultured human airway smooth muscle cells from 0.05 to 0.4 Hz.

Authors:  G N Maksym; B Fabry; J P Butler; D Navajas; D J Tschumperlin; J D Laporte; J J Fredberg
Journal:  J Appl Physiol (1985)       Date:  2000-10

3.  Viscoelastic properties of single attached cells under compression.

Authors:  Emiel A G Peeters; Cees W J Oomens; Carlijn V C Bouten; Dan L Bader; Frank P T Baaijens
Journal:  J Biomech Eng       Date:  2005-04       Impact factor: 2.097

4.  Force microscopy of nonadherent cells: a comparison of leukemia cell deformability.

Authors:  Michael J Rosenbluth; Wilbur A Lam; Daniel A Fletcher
Journal:  Biophys J       Date:  2006-01-27       Impact factor: 4.033

Review 5.  Particle-tracking microrheology of living cells: principles and applications.

Authors:  Denis Wirtz
Journal:  Annu Rev Biophys       Date:  2009       Impact factor: 12.981

6.  Dimensional and mechanical dynamics of active and stable edges in motile fibroblasts investigated by using atomic force microscopy.

Authors:  C Rotsch; K Jacobson; M Radmacher
Journal:  Proc Natl Acad Sci U S A       Date:  1999-02-02       Impact factor: 11.205

Review 7.  Actin-based cell motility and cell locomotion.

Authors:  T J Mitchison; L P Cramer
Journal:  Cell       Date:  1996-02-09       Impact factor: 41.582

8.  Passive mechanical properties of human leukocytes.

Authors:  G W Schmid-Schönbein; K L Sung; H Tözeren; R Skalak; S Chien
Journal:  Biophys J       Date:  1981-10       Impact factor: 4.033

Review 9.  Connections between single-cell biomechanics and human disease states: gastrointestinal cancer and malaria.

Authors:  S Suresh; J Spatz; J P Mills; A Micoulet; M Dao; C T Lim; M Beil; T Seufferlein
Journal:  Acta Biomater       Date:  2005-01       Impact factor: 8.947

Review 10.  Biomechanics and biophysics of cancer cells.

Authors:  Subra Suresh
Journal:  Acta Biomater       Date:  2007-05-30       Impact factor: 8.947

View more
  6 in total

1.  Blood viscoelasticity measurement using steady and transient flow controls of blood in a microfluidic analogue of Wheastone-bridge channel.

Authors:  Yang Jun Kang; Sang-Joon Lee
Journal:  Biomicrofluidics       Date:  2013-10-29       Impact factor: 2.800

2.  Triangular correlation (TrC) between cancer aggressiveness, cell uptake capability, and cell deformability.

Authors:  Yifat Brill-Karniely; Dvir Dror; Tal Duanis-Assaf; Yoel Goldstein; Ouri Schwob; Talya Millo; Natalie Orehov; Tal Stern; Mohammad Jaber; Netanel Loyfer; Margarita Vosk-Artzi; Hadar Benyamini; Diane Bielenberg; Tommy Kaplan; Yosef Buganim; Meital Reches; Ofra Benny
Journal:  Sci Adv       Date:  2020-01-15       Impact factor: 14.136

3.  Love Wave Sensor with High Penetration Depth for Potential Application in Cell Monitoring.

Authors:  Pedro A Segura Chávez; Jérémy Bonhomme; Mohamed Lamine Fayçal Bellaredj; Lucile Olive; Denis Beyssen; Mourad Oudich; Paul G Charette; Frédéric Sarry
Journal:  Biosensors (Basel)       Date:  2022-01-24

4.  Resistance to fluid shear stress is a conserved biophysical property of malignant cells.

Authors:  J Matthew Barnes; Jones T Nauseef; Michael D Henry
Journal:  PLoS One       Date:  2012-12-03       Impact factor: 3.240

5.  A membrane-based microfluidic device for mechano-chemical cell manipulation.

Authors:  Agnese Ravetto; Imo E Hoefer; Jaap M J den Toonder; Carlijn V C Bouten
Journal:  Biomed Microdevices       Date:  2016-04       Impact factor: 2.838

6.  Human mesenchymal stem cell basal membrane bending on gratings is dependent on both grating width and curvature.

Authors:  Yukai Zeng; Sum Thai Wong; Soo Kng Teo; Kam W Leong; Keng-Hwee Chiam; Evelyn K F Yim
Journal:  Sci Rep       Date:  2018-04-24       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.