The relative and absolute reliability of leg muscle strength testing by a handheld dynamometer.

Yen-Mou Lu1, Jau-Hong Lin, Shih-Fen Hsiao, Mei-Fang Liu, Shu-Mei Chen, Yi-Jing Lue.   

Abstract

To examine the relative and absolute interrater reliability of handheld dynamometers (HHD) for assessing the lower extremity muscle strength, maximal voluntary contractions (MVCs) of 16 young adults for bilateral hip and knee muscles were tested using the break method. Three MVCs of each muscle group were required for obtaining the muscle strength. Participants' muscle strengths were tested by 2 raters. The intraclass correlation coefficients (ICCs) and the smallest real differences (SRD) were used to examine the relative and absolute reliabilities, and the Bland-Altman analyses were used to check whether systematic bias exists. The results showed that the relative reliabilities of all muscle groups were excellent (ICCs = 0.83-0.92) except for the knee extensors (ICC = 0.60). The SRD represents the smallest difference that indicates a real change for a single subject. The SRD% of all muscle groups was acceptable (ranging from 8.4 to 22.8 %), with the hip extensors being the smallest and knee extensors being the largest. The reliability of the knee extensors was unsatisfactory because of poor relative and absolute reliabilities and systematic bias. In addition to assessing the relative reliability in strength measurement, the absolute reliability provides the data of the measurement error, which is useful information in clinical practice to know whether the change in strength of a subject is real. Hand-held dynamometer is a reliable tool for quantifying most of the hip and knee strength except for the knee extensors. Modifying the measuring technique for knee extension is needed in future studies to improve the reliability.

Entities:  

Mesh:

Year:  2011        PMID: 20838248     DOI: 10.1519/JSC.0b013e3181d650a6

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  16 in total

1.  Treatment of hamstring strain in a collegiate pole-vaulter integrating dry needling with an eccentric training program: a resident's case report.

Authors:  Scott C Dembowski; Richard B Westrick; Edo Zylstra; Michael R Johnson
Journal:  Int J Sports Phys Ther       Date:  2013-06

2.  TEST-RETEST RELIABILITY OF TWO CLINICAL TESTS FOR THE ASSESSMENT OF HIP ABDUCTOR ENDURANCE IN HEALTHY FEMALES.

Authors:  Joachim Van Cant; Gregory Dumont; Laurent Pitance; Christophe Demoulin; Véronique Feipel
Journal:  Int J Sports Phys Ther       Date:  2016-02

3.  Validation of the Chinese version of the Boston Carpal Tunnel Questionnaire.

Authors:  Yi-Jing Lue; Yen-Mou Lu; Gau-Tyan Lin; Ya-Fen Liu
Journal:  J Occup Rehabil       Date:  2014-03

4.  Effect of intradialytic exercise on geriatric issues in older patients undergoing hemodialysis: a single-center non-randomized controlled study.

Authors:  Hiroki Yabe; Kenichi Kono; Tomoya Yamaguchi; Naomi Yamada; Yumiko Ishikawa; Yoshiko Yamaguchi; Hisanori Azekura
Journal:  Int Urol Nephrol       Date:  2022-05-07       Impact factor: 2.266

5.  Validating the Cambridge Protocol: Reliability of Hip Muscle Strength Measurements Using a Motorized Dynamometer and Electromyography.

Authors:  Arman Memarzadeh; Andrew Paul Morrison; Viviane Merzbach; Michael Ferrandino; Arvind Arora; Leica S Claydon-Mueller; Vikas Khanduja
Journal:  Sports Health       Date:  2022-02-01       Impact factor: 4.355

6.  Comparative assessment of knee extensor and flexor muscle strength measured using a hand-held vs. isokinetic dynamometer.

Authors:  Guillaume Muff; Stéphane Dufour; Alain Meyer; François Severac; Fabrice Favret; Bernard Geny; Jehan Lecocq; Marie-Eve Isner-Horobeti
Journal:  J Phys Ther Sci       Date:  2016-09-29

7.  Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

Authors:  Naoko Ushiyama; Yasushi Kurobe; Kimito Momose
Journal:  J Phys Ther Sci       Date:  2017-11-24

8.  Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis - an inter-rater study.

Authors:  Erik Poulsen; Henrik Wulff Christensen; Jeannette Østergaard Penny; Søren Overgaard; Werner Vach; Jan Hartvigsen
Journal:  BMC Musculoskelet Disord       Date:  2012-12-06       Impact factor: 2.362

9.  Novel Use of the Nintendo Wii Board for Measuring Isometric Lower Limb Strength: A Reproducible and Valid Method in Older Adults.

Authors:  Martin Gronbech Jorgensen; Stig Andersen; Jesper Ryg; Tahir Masud
Journal:  PLoS One       Date:  2015-10-07       Impact factor: 3.240

10.  Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

Authors:  Madeleine Wertsén; Manne Stenberg
Journal:  Clin Exp Dent Res       Date:  2017-04-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.