Seasonal mapping of NICU temperature.

Karen A Thomas1, Almita Magbalot, Kelley Shinabarger, Larisa Mokhnach, Marilyn Anderson, Kristi Diercks, April Millar, Lauren Thorngate, Wendy Walker, Nancy Dilback, Maureen Berkan.   

Abstract

PURPOSE: To create a thermal map of ambient air, radiant, and evaporative temperatures and humidity throughout the NICU nursery by season across a calendar year.
SUBJECTS: Each cubicle of the 32-bed NICU, distributed across 5 rooms, in a level III nursery was measured.
METHODS: Temperatures were recorded at a consistent time on one day during January, April, July, and October. MAIN OUTCOME MEASURES: : An electronic monitor (QUESTemp ° 34; Quest Technologies, Oconomowoc, Wisconsin) was used to measure dry bulb, wet bulb, and globe thermometer temperatures.
RESULTS: Analysis of variance revealed statistically significant (P ≤ .000) differences in season, room, and season by room interaction. Room ambient air temperatures differed by less than 2 ° F across season. Radiant temperature paralleled air temperature. Humidity, the predominant difference across season, produced evaporative temperatures considerably lower than room air temperature, and the gradient between mean nursery dry bulb temperature and wet bulb temperature was 9.3 ° F in summer and 16.8 ° F in winter.
CONCLUSIONS: The thermal map revealed seasonal thermal differences, particularly in humidity level and evaporative temperature. Room temperature alone does not reflect the total thermal environment. Recommendations include periodic assessment of nurseries along with air, evaporative, and radiant temperatures as well as humidity to fully appreciate the impact of the thermal environment on infants.

Entities:  

Mesh:

Year:  2010        PMID: 20838081     DOI: 10.1097/ANC.0b013e3181f1c4b1

Source DB:  PubMed          Journal:  Adv Neonatal Care        ISSN: 1536-0903            Impact factor:   1.968


  1 in total

1.  Assessing neonatal heat balance and physiological strain in newborn infants nursed under radiant warmers in intensive care with fentanyl sedation.

Authors:  Yannick Molgat-Seon; Thierry Daboval; Shirley Chou; Ollie Jay
Journal:  Eur J Appl Physiol       Date:  2014-08-13       Impact factor: 3.078