Literature DB >> 20831396

Ultrasound and joint mobilizations for achieving normal wrist range of motion after injury or surgery: a case series.

David O Draper1.   

Abstract

CONTEXT: Regaining full, active range of motion (AROM) after trauma to the wrist is difficult.
OBJECTIVE: To report the cases of 6 patients who lacked full range of motion (ROM) in the wrist due to trauma. The treatment regimen was thermal 3-MHz ultrasound and joint mobilizations.
DESIGN: Case series.
SETTING: University therapeutic modalities laboratory. PATIENTS OR OTHER PARTICIPANTS: Six patients (2 women, 4 men) from the university population lacked a mean AROM of 21.7° of flexion and 26.8° of extension approximately 2.1 years after trauma or surgery. MAIN OUTCOME MEASURE(S): I assessed changes in flexion and extension AROM before and after each treatment. Treatment consisted of 6 minutes of 3-MHz continuous ultrasound at an average intensity of 1.4 W/cm(2) on the dorsal and volar aspects of the wrist, immediately followed by approximately 10 minutes of joint mobilizations. After posttreatment ROM was recorded, ice was applied to the area for about 20 minutes. Once the patient achieved full AROM or did not improve on 2 consecutive visits, he or she was discharged from the study.
RESULTS: By the sixth treatment, 5 participants achieved normal flexion AROM, and 3 exceeded the norm. All 6 achieved normal extension AROM, and 4 exceeded the norm. All returned to normal activities and normal use of their hands. One month later, they had, on average, maintained 93% of their final measurements.
CONCLUSIONS: A combination of thermal ultrasound and joint mobilizations was effective in restoring AROM to wrists lacking ROM after injury or surgery.

Entities:  

Mesh:

Year:  2010        PMID: 20831396      PMCID: PMC2938322          DOI: 10.4085/1062-6050-45.5.486

Source DB:  PubMed          Journal:  J Athl Train        ISSN: 1062-6050            Impact factor:   2.860


  13 in total

1.  Temperature change in human muscle during and after pulsed short-wave diathermy.

Authors:  D O Draper; K Knight; T Fujiwara; J C Castel
Journal:  J Orthop Sports Phys Ther       Date:  1999-01       Impact factor: 4.751

2.  Three-MHz Ultrasound Heats Deeper Into the Tissues Than Originally Theorized.

Authors:  Bradley T Hayes; Mark A Merrick; Michelle A Sandrey; Mitchell L Cordova
Journal:  J Athl Train       Date:  2004-09       Impact factor: 2.860

3.  Rate of Temperature Decay in Human Muscle Following 3 MHz Ultrasound: The Stretching Window Revealed.

Authors:  D O Draper; M D Ricard
Journal:  J Athl Train       Date:  1995-10       Impact factor: 2.860

4.  The reliability of joint measurement.

Authors:  J L Low
Journal:  Physiotherapy       Date:  1976-06-10       Impact factor: 3.358

5.  Use of pulsed shortwave diathermy and joint mobilization to increase ankle range of motion in the presence of surgical implanted metal: A case series.

Authors:  Cindy Seiger; David O Draper
Journal:  J Orthop Sports Phys Ther       Date:  2006-09       Impact factor: 4.751

6.  Rate of temperature increase in human muscle during 1 MHz and 3 MHz continuous ultrasound.

Authors:  D O Draper; J C Castel; D Castel
Journal:  J Orthop Sports Phys Ther       Date:  1995-10       Impact factor: 4.751

7.  Reliability of goniometric measurements.

Authors:  D C Boone; S P Azen; C M Lin; C Spence; C Baron; L Lee
Journal:  Phys Ther       Date:  1978-11

8.  Comparison of the early response to two methods of rehabilitation in adhesive capsulitis.

Authors:  Fusun Guler-Uysal; Erkan Kozanoglu
Journal:  Swiss Med Wkly       Date:  2004-06-12       Impact factor: 2.193

9.  Heat distribution in the lower leg from pulsed short-wave diathermy and ultrasound treatments.

Authors:  C L Garrett; D O Draper; K L Knight
Journal:  J Athl Train       Date:  2000-01       Impact factor: 2.860

10.  Secondary injury after musculoskeletal trauma: a review and update.

Authors:  Mark A Merrick
Journal:  J Athl Train       Date:  2002-04       Impact factor: 2.860

View more
  5 in total

1.  Pulsed shortwave diathermy and joint mobilizations for achieving normal elbow range of motion after injury or surgery with implanted metal: a case series.

Authors:  David O Draper
Journal:  J Athl Train       Date:  2014 Nov-Dec       Impact factor: 2.860

2.  Intramuscular Heating Characteristics of Multihour Low-Intensity Therapeutic Ultrasound.

Authors:  Justin H Rigby; Rebecca M Taggart; Kelly L Stratton; George K Lewis; David O Draper
Journal:  J Athl Train       Date:  2015-10-28       Impact factor: 2.860

3.  Post-operative rehabilitation in a traumatic rare radial nerve palsy managed with tendon transfers: a case report.

Authors:  Pratik Phansopkar; Vrushali Athawale; Aachal Birelliwar; Waqar Naqvi; Swapna Kamble
Journal:  Pan Afr Med J       Date:  2020-06-30

4.  Overview of ultrasound usage trends in orthopedic and sports physiotherapy.

Authors:  Wouber Herickson de Brito Vieira; Kardec Alecxandro Aguiar; Kimberly Moreira da Silva; Pablo Miranda Canela; Flávio Santos da Silva; Bento João Abreu
Journal:  Crit Ultrasound J       Date:  2012-05-28

5.  Effects of therapeutic ultrasound on range of motion and stretch pain.

Authors:  Katsuyuki Morishita; Hiroshi Karasuno; Yuka Yokoi; Kazunori Morozumi; Hisayoshi Ogihara; Toshikazu Ito; Masaaki Hanaoka; Takayuki Fujiwara; Tetsuya Fujimoto; Koji Abe
Journal:  J Phys Ther Sci       Date:  2014-05-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.