Literature DB >> 20831367

Safety of oscillating-rotating powered brushes compared to manual toothbrushes: a systematic review.

Fridus A Van der Weijden1, Shelly L Campbell, Christof E Dörfer, Carlos González-Cabezas, Dagmar E Slot.   

Abstract

BACKGROUND: Oscillating-rotating power toothbrushes have been proven clinically efficacious. To our knowledge, a comprehensive review of all clinical and laboratory investigations solely comparing the safety of these toothbrushes to the standard of care (i.e., manual toothbrushes) has not been published. The aim of this systematic review is to examine the literature concerning the relative soft and/or hard tissue safety outcomes with the use of oscillating-rotating toothbrushes compared to manual toothbrushes.
METHODS: With the use of electronic databases of the National Library of Medicine (PubMed-MEDLINE), the Cochrane Central Register of Controlled Trials (Cochrane-CENTRAL), and the Excerpta Medical Database (EMBASE), a search of in vivo and in vitro trials through May 2010 was conducted to identify appropriate studies that evaluated the effects of an oscillating-rotating power toothbrush compared to a manual toothbrush with respect to soft and/or hard tissue safety. Eligible trials incorporated a safety evaluation as a primary or secondary outcome parameter (i.e., gingival recession, observed/reported adverse events, and hard tissue effects) or used a surrogate parameter (i.e., stained gingival abrasion and brushing force) to assess safety. Data extraction for the primary- and surrogate-measure safety studies, which included mean values and SDs when available, and a meta-analysis of the gingival recession data were performed.
RESULTS: Independent screening of the titles and abstracts of 697 PubMed-MEDLINE, 436 Cochrane-CENTRAL, and 664 EMBASE papers resulted in 35 publications that met the eligibility criteria. The mean change in gingival recession was not significantly different among toothbrush groups in the two selected trials with safety as a primary outcome (weighted mean difference: 0.03). A meta-analysis of the five trials that evaluated safety with a surrogate parameter was not possible; however, there were no significant between-group differences at the study end in any trial. A descriptive analysis of the 24 selected studies assessing safety as a secondary outcome revealed few brushing-related adverse events. The heterogeneity in objectives and methodology of the four in vitro trials that met the eligibility criteria precluded generalization of the results.
CONCLUSION: A large body of published research in the preceding 2 decades has consistently shown oscillating-rotating toothbrushes to be safe compared to manual toothbrushes, demonstrating that these power toothbrushes do not pose a clinically relevant concern to hard or soft tissues.

Entities:  

Mesh:

Year:  2010        PMID: 20831367     DOI: 10.1902/jop.2010.100393

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  12 in total

1.  Bristle splaying and its effect on pre-existing gingival recession-a 12-month randomized controlled trial.

Authors:  C Graetz; A Plaumann; N Heinevetter; S Sälzer; J Bielfeldt; C E Dörfer
Journal:  Clin Oral Investig       Date:  2016-10-31       Impact factor: 3.573

2.  Effects of interactive power toothbrush with or without application assistance on the plaque, gingivitis, and gingival abrasion among dental students: a randomized controlled clinical trial.

Authors:  Sühan Gürbüz; Zeynep Turgut Çankaya; Ekin Cinal; Eda Gizem Koçyiğit; Ayşen Bodur
Journal:  Clin Oral Investig       Date:  2022-05-26       Impact factor: 3.606

3.  Brushing force of manual and sonic toothbrushes affects dental hard tissue abrasion.

Authors:  Annette Wiegand; John Patrik Matthias Burkhard; Florin Eggmann; Thomas Attin
Journal:  Clin Oral Investig       Date:  2012-07-13       Impact factor: 3.573

Review 4.  Are bristle stiffness and bristle end-shape related to adverse effects on soft tissues during toothbrushing? A systematic review.

Authors:  Nicolle Ranzan; Francisco Wilker Mustafa Gomes Muniz; Cassiano Kuchenbecker Rösing
Journal:  Int Dent J       Date:  2018-08-27       Impact factor: 2.607

5.  Comparison of Effectiveness of Manual Orthodontic, Powered and Sonic Toothbrushes on Oral Hygiene of Fixed Orthodontic Patients.

Authors:  Ruchi Sharma; Mridula Trehan; Sunil Sharma; Vikas Jharwal; Nidhi Rathore
Journal:  Int J Clin Pediatr Dent       Date:  2015-09-11

Review 6.  Safety and Design Aspects of Powered Toothbrush-A Narrative Review.

Authors:  Clarence Ng; James Kit Hon Tsoi; Edward C M Lo; And Jukka P Matinlinna
Journal:  Dent J (Basel)       Date:  2020-02-05

7.  ISP Good Clinical Practice Recommendations for the management of Dentin Hypersensitivity.

Authors:  Vishakha Grover; Ashish Kumar; Ashish Jain; Anirban Chatterjee; Harpreet Singh Grover; Nymphea Pandit; Anurag Satpathy; Baiju Radhamoni Madhavan Pillai; Anil Melath; Deepa Dhruvakumar; Roshani Thakur; Nilesh V Joshi; Neeraj Deshpande; Himanshu Dadlani; A Archana Meenakshi; K P Ashok; K Vinathi Reddy; Meenu Taneja Bhasin; Sanjeev Kumar Salaria; Abhishek Verma; Rajesh Prabhakar Gaikwad; Hemant Darekar; Ramesh Amirisetty; Mangesh Phadnaik; Vaibhav Karemore; Ravindranath Dhulipalla; Dhawal Mody; Tushar Shri Rao; Swarna Chakarpani; V Ranganath
Journal:  J Indian Soc Periodontol       Date:  2022-07-02

8.  Gingival abrasion and recession in manual and oscillating-rotating power brush users.

Authors:  N A M Rosema; R Adam; J M Grender; E Van der Sluijs; S C Supranoto; G A Van der Weijden
Journal:  Int J Dent Hyg       Date:  2014-05-28       Impact factor: 2.477

9.  Hand to Mouth: A Systematic Review and Meta-Analysis of the Association between Rheumatoid Arthritis and Periodontitis.

Authors:  Nicholas R Fuggle; Toby O Smith; Arvind Kaul; Nidhi Sofat
Journal:  Front Immunol       Date:  2016-03-02       Impact factor: 7.561

10.  A 5-week randomized clinical evaluation of a novel electric toothbrush head with regular and tapered bristles versus a manual toothbrush for reduction of gingivitis and plaque.

Authors:  Renzo Alberto Ccahuana-Vasquez; Ralf Adam; Erinn Conde; Julie M Grender; Pamela Cunningham; C Ram Goyal; Jimmy Qaqish
Journal:  Int J Dent Hyg       Date:  2018-12-19       Impact factor: 2.477

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.