Literature DB >> 20831206

Development of a troponin I biosensor using a peptide obtained through phage display.

Jun Wu1, Donald M Cropek, Alan C West, Scott Banta.   

Abstract

A small synthetic peptide with nanomolar affinity for cardiac troponin I (TnI), previously identified from a polyvalent phage displayed library, has been immobilized on a gold surface for TnI detection. The binding affinity of gold-immobilized peptides for TnI was studied and compared with that of phage-immobilized peptides. Quartz crystal microbalance (QCM), cyclic voltammetry, and electrochemical impedance spectroscopy (EIS) were used to monitor both the immobilization and target binding processes. All three techniques show that the binding is specific for TnI as compared to a streptavidin (SA) control. The response curves obtained at TnI concentrations ranging from 0 to 10 μg/mL, using both QCM and EIS, were also compared. For the EIS measurements, the sensitivity was 0.30 ± 0.030 normalized impedance/(μg/mL) and the limit of detection (LOD) was 0.34 μg/mL. Using the QCM, a sensitivity of 18 ± 1 Hz/(μg/mL) was obtained, corresponding to an LOD of 0.11 μg/mL. Although the QCM demonstrated a lower LOD as compared to EIS, the latter technique exhibited a larger linear dynamic range than QCM. In a relevant tissue culture milieu, Minimum Essential Media (MEM), the sensitivity of the EIS measurement was greater than that obtained in a phosphate buffer system (PBS). The kinetics of target binding using QCM were analyzed by two independent methods, and the dissociation constants (K(D) = 66 ± 4 nM and 17 ± 8 nM) were an order of magnitude higher than that calculated for the polyvalent phage particles (K(D) = 2.5 ± 0.1 nM). Even though the affinity of the immobilized peptides for TnI was somewhat reduced, overall, these results demonstrate that peptides obtained from the biopanning of phage display libraries can be readily used as sensing probes in biosensor development.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20831206     DOI: 10.1021/ac101657h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

1.  Monitoring the conformational changes of an intrinsically disordered peptide using a quartz crystal microbalance.

Authors:  Oren Shur; Jun Wu; Donald M Cropek; Scott Banta
Journal:  Protein Sci       Date:  2011-04-08       Impact factor: 6.725

2.  Site-directed dual bioprobes inducing single-step nano-sandwich assay for the detection of cardiac troponin I.

Authors:  Saloni Kakkar; Sakshi Chauhan; Rajni Bala; Virendra Kumar; Manojkumar Rohit; Vijayender Bhalla
Journal:  Mikrochim Acta       Date:  2022-09-02       Impact factor: 6.408

3.  Copper Sensing with a Prion Protein Modified Nanopipette.

Authors:  Paolo Actis; Alex McDonald; David Beeler; Boaz Vilozny; Glenn Millhauser; Nader Pourmand
Journal:  RSC Adv       Date:  2012-09-26       Impact factor: 3.361

4.  Rapid development of new protein biosensors utilizing peptides obtained via phage display.

Authors:  Jun Wu; Jong Pil Park; Kevin Dooley; Donald M Cropek; Alan C West; Scott Banta
Journal:  PLoS One       Date:  2011-10-07       Impact factor: 3.240

5.  Functional epitope core motif of the Anaplasma marginale major surface protein 1a and its incorporation onto bioelectrodes for antibody detection.

Authors:  Paula S Santos; Rafael Nascimento; Luciano P Rodrigues; Fabiana A A Santos; Paula C B Faria; João R S Martins; Ana G Brito-Madurro; João M Madurro; Luiz R Goulart
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

6.  A nanostructured piezoelectric immunosensor for detection of human cardiac troponin T.

Authors:  Rosana A S Fonseca; Joilson Ramos-Jesus; Lauro T Kubota; Rosa F Dutra
Journal:  Sensors (Basel)       Date:  2011-11-16       Impact factor: 3.576

Review 7.  Virus outbreaks in chemical and biological sensors.

Authors:  Inseong Hwang
Journal:  Sensors (Basel)       Date:  2014-07-25       Impact factor: 3.576

Review 8.  Phage Display in the Quest for New Selective Recognition Elements for Biosensors.

Authors:  Riikka Peltomaa; Elena Benito-Peña; Rodrigo Barderas; María C Moreno-Bondi
Journal:  ACS Omega       Date:  2019-07-03

9.  Development of peptide biosensor for the detection of dengue fever biomarker, nonstructural 1.

Authors:  Ji Hong Kim; Chae Hwan Cho; Myung Yi Ryu; Jong-Gil Kim; Sei-Jung Lee; Tae Jung Park; Jong Pil Park
Journal:  PLoS One       Date:  2019-09-25       Impact factor: 3.240

10.  Peptide Functionalized Gold Nanorods for the Sensitive Detection of a Cardiac Biomarker Using Plasmonic Paper Devices.

Authors:  Sirimuvva Tadepalli; Zhifeng Kuang; Qisheng Jiang; Keng-Ku Liu; Marilee A Fisher; Jeremiah J Morrissey; Evan D Kharasch; Joseph M Slocik; Rajesh R Naik; Srikanth Singamaneni
Journal:  Sci Rep       Date:  2015-11-10       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.