Fast and memory-efficient Monte Carlo-based image reconstruction for whole-body PET.

Long Zhang1, Steven Staelens, Roel Van Holen, Jan De Beenhouwer, Jeroen Verhaeghe, Iwan Kawrakow, Stefaan Vandenberghe.   

Abstract

PURPOSE: Several studies have shown the benefit of an accurate system modeling using Monte Carlo techniques. For state-of-the-art whole-body positron emission tomography (PET) scanners, Monte Carlo-based image reconstruction is associated with a significant computational cost to calculate the system matrix as well as a large memory capacity to store it. In this article, the authors present a simulation-reconstruction framework to solve these problems on the Philips Gemini GS PET scanner.
METHODS: A fast, realistic system matrix simulation module was developed using egs_pet, which is an efficient PET simulation code based on EGSnrc. The generated system matrix was then used in a rotator-based ordered subset expectation maximization (OS-EM) algorithm, which exploits the rotational symmetry of a cylindrical PET scanner. The system matrix was further compressed by using sparse storage techniques.
RESULTS: The system matrix simulation took five days on 50 cores of Xeon 2.66 GHz, resulting in a system matrix of 2.01 GB. The entire system matrix could be stored in the main memory of a standard personal computer. The image quality in terms of contrast-noise trade-offs was considerably improved compared to a standard OS-EM algorithm. The image quality was also compared to the clinical software on the scanner using routine parameter settings. The contrast recovery coefficient of small hot spheres and cold spheres was significantly improved.
CONCLUSIONS: The results indicated that the proposed framework could be used for this PET scanner with improved image quality. This method could also be applied to other state-of-the-art whole-body PET scanners and preclinical PET scanners with a similar shape.

Entities:  

Mesh:

Year:  2010        PMID: 20831074     DOI: 10.1118/1.3455287

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

2.  Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography.

Authors:  Krishnendu Saha; Kenneth J Straus; Yu Chen; Stephen J Glick
Journal:  J Appl Phys       Date:  2014-08-28       Impact factor: 2.546

3.  High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid.

Authors:  J Cabello; J E Gillam; M Rafecas
Journal:  Int J Biomed Imaging       Date:  2012-04-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.