Literature DB >> 20830736

Glucose effectiveness and insulin sensitivity measurements derived from the non-insulin-assisted minimal model and the clamp techniques are concordant.

Jan Erik Henriksen1, Frank Alford, Glenn Ward, Peter Thye-Rønn, Klaus Levin, Ole Hother-Nielsen, Christian Rantzau, Ray Boston, Henning Beck-Nielsen.   

Abstract

BACKGROUND: We investigated the concordance between glucose effectiveness (SG) and insulin sensitivity (SI), derived from the unmodified dynamic non-insulin-assisted intravenous glucose tolerance test (IVGTT) implemented by SG(MM) and SI(MM); simulation analysis and modelling/conversational interaction (SAAM/CONSAM) versus the eu/hyperglycaemic basal insulinaemic and the euglycaemic hyperinsulinaemic clamp (SG(CLAMP) and SI(CLAMP)).
METHODS: Twenty-seven of 30 normoglycaemic subjects completed a (1) euglycaemic hyperinsulinaemic clamp, (2) 6-h eu/hyperglycaemic near-normoinsulinaemic pancreatic clamp with hyperglycaemia present over the final 2 h of the clamp (Day 2 study), (3) identical clamp to (2) but with euglycaemia maintained over the entire 6 h (Day 3 study) and (4) IVGTT. SG(CLAMP) was calculated in two ways based on data from study (2) alone (Day 2 SG(CLAMP210-240')) or from data from study day (2) and (3) (Day 2-3 SG(CLAMP330-360')).
RESULTS: SG(MM) was unrelated to the magnitude of endogenous insulin release (AIR). The single-day (Day 2) and two-day (Day 2 and 3) SG(CLAMP) protocols correlated (r = 0.72, p = 0.003), but SG(CLAMP210-240') was significantly (p = 0.001) higher than SG(CLAMP330-360'). Employing the Day 2 and 3 SG(CLAMP) protocol, the whole body SG(CLAMP330-360') was similar to SG(MM) (1.80 ± 0.82 versus 1.73 ± 0.58 dL/min) and correlated (r = 0.45, p < 0.02). SG(CLAMP210-240') did not correlate with SG(MM) (r = 0.24). SI(MM) and SI(CLAMP) were similar (0.093 ± 0.060 versus 0.087 ± 0.029 dL/min per mU/L) and correlated (r = 0.76, p < 0.001).
CONCLUSIONS: The time-dependent increase in glucose disposal observed during a prolonged 6-h clamp significantly influences the estimation of SG(CLAMP), and significant concordance coefficients are observed between SG(MM), and SG(CLAMP330-360'), and SI(MM) and SI(CLAMP).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20830736     DOI: 10.1002/dmrr.1127

Source DB:  PubMed          Journal:  Diabetes Metab Res Rev        ISSN: 1520-7552            Impact factor:   4.876


  3 in total

1.  Assessing the predictive accuracy of oral glucose effectiveness index using a calibration model.

Authors:  Michael Glicksman; Shivraj Grewal; Shrayus Sortur; Brent S Abel; Sungyoung Auh; Trudy R Gaillard; Kwame Osei; Ranganath Muniyappa
Journal:  Endocrine       Date:  2018-11-06       Impact factor: 3.633

2.  An Analysis of Glucose Effectiveness in Subjects With or Without Type 2 Diabetes via Hierarchical Modeling.

Authors:  Shihao Hu; Yuzhi Lu; Andrea Tura; Giovanni Pacini; David Z D'Argenio
Journal:  Front Endocrinol (Lausanne)       Date:  2021-03-29       Impact factor: 5.555

3.  Glucose Effectiveness from Short Insulin-Modified IVGTT and Its Application to the Study of Women with Previous Gestational Diabetes Mellitus.

Authors:  Micaela Morettini; Carlo Castriota; Christian Göbl; Alexandra Kautzky-Willer; Giovanni Pacini; Laura Burattini; Andrea Tura
Journal:  Diabetes Metab J       Date:  2020-01-13       Impact factor: 5.376

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.