Mechanical testing of a modified stabilisation method for tibial tuberosity advancement.

S Etchepareborde1, N Barthelemy, J Mills, F Pascon, G R Ragetly, M Balligand.   

Abstract

OBJECTIVES: This in vitro study evaluated three modified techniques of tibial tuberosity advancement (TTA). Loads to failure were calculated for each technique.
METHODS: A 9 mm TTA procedure was performed in the tibiae of dogs weighing between 32 and 38 kg. In group 1 (n = 12), the distal part of the tibial crest was left attached to the tibia by the cranial cortex, and a figure-of-eight wire was added for stabilisation. In group 2 (n = 12), the tibial crest was left attached but no additional device was used for stabilisation. In group 3 (n = 12), the tibial crest was completely separated from the tibia and fixed by a figure-of-eight wire so that, in this group, only the wire opposed avulsion of the tibial crest. Unidirectional axial force was applied via the patella to determine the maximal load to failure of the model.
RESULTS: There was no significant difference between group 1 and group 2. These two groups both had a significantly stronger construct than that of group 3. CLINICAL SIGNIFICANCE: We described modifications to the TTA procedure without plate fixation that warrant clinical investigation. When the crest is broken during its advancement, the tension sustained by the repair is significantly weaker from a biomechanical point of view and the use of such a repair clinically is not recommended by the authors.

Entities:  

Mesh:

Year:  2010        PMID: 20830458     DOI: 10.3415/VCOT-09-08-0088

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  2 in total

1.  Effect of proximal translation of the osteotomized tibial tuberosity during tibial tuberosity advancement on patellar position and patellar ligament angle.

Authors:  Jack D Neville-Towle; Mariano Makara; Kenneth A Johnson; Katja Voss
Journal:  BMC Vet Res       Date:  2017-01-09       Impact factor: 2.741

2.  Mechanical Testing of the New Cage for Tibial Tuberosity Advancement with the Cranial Implant Fixation (TTA CF) Technique-Ex Vivo Study on Sheep Model.

Authors:  Yauheni Zhalniarovich; Paulina Przyborowska-Zhalniarovich; Angelika Tobolska; Marta Mieszkowska; Justyna Abako; Magdalena Morawska-Kozłowska; Marcin Mieszkowski; Dariusz Onichimowski
Journal:  Animals (Basel)       Date:  2022-08-09       Impact factor: 3.231

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.