Literature DB >> 20825595

Saline volume necessary to achieve predetermined intraluminal pressures during leak testing of small intestinal biopsy sites in the dog.

Katrin Saile1, Harry W Boothe, Dawn M Boothe.   

Abstract

OBJECTIVE: To determine the volume of saline needed to achieve targeted intraluminal pressures during leak testing of closed jejunal biopsy sites in the dog. STUDY
DESIGN: Experimental. ANIMALS: Dogs (n=38).
METHODS: Jejunal biopsies in dogs were performed and closed using 3-4 full thickness simple interrupted sutures. Saline volumes needed to achieve 2 predetermined intraluminal pressures (20 and 34 cm water [15 and 25 mmHg]) in a 10 cm canine jejunal segment containing a closed biopsy site using 2 methods of luminal occlusion were recorded.
RESULTS: The 95% confidence intervals for the volume of saline needed to achieve 20 and 34 cm water intraluminal pressure were 10.9-13.6 and 16.3-19.0 mL, respectively with digital occlusion and 8.5-11.1 and 12.1-14.8 mL, respectively with Doyen occlusion. Correlation between volume of saline instilled and the pressure achieved was 0.76 for digital occlusion and 0.86 for Doyen occlusion.
CONCLUSION: Correlation between volume of saline instilled and pressure achieved was greater with Doyen than digital occlusion. CLINICAL RELEVANCE: For canine jejunum, saline volumes of 16.3-19 mL (digital occlusion) and 12.1-14.8 mL (Doyen occlusion) can be used to achieve intraluminal pressures of 34 cm water during leak testing of a 10 cm segment containing a closed biopsy site. © Copyright 2010 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20825595     DOI: 10.1111/j.1532-950X.2010.00730.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  4 in total

1.  Effect of enteric biopsy closure orientation on enteric circumference and volume of saline needed for leak testing.

Authors:  Brad M Matz; Harry W Boothe; James C Wright; Dawn M Boothe
Journal:  Can Vet J       Date:  2014-01       Impact factor: 1.008

2.  Influence of stapler type on in vitro leakage pressures and location of functional end-to-end stapled anastomoses.

Authors:  Kathryn M Paskoff; Katelyn C Hlusko; Corrine L Buirkle; Whitney S Coggeshall; Brad M Matz; Daniel S Linden
Journal:  Can J Vet Res       Date:  2022-04       Impact factor: 0.897

3.  Investigation of leakage holes created by four needle types used for closure of canine enterotomies.

Authors:  Konstantinos Mitsou; Lysimachos G Papazoglou; Ioannis Savvas; Emmanouil Tzimtzimis
Journal:  Open Vet J       Date:  2018-11-02

4.  An alternative asymmetric figure-of-eight single-layer suture technique for bowel anastomosis in an in vitro porcine model.

Authors:  Chen Liu; Yewen Wang; Ai-Rong Zhao; Feng-Ai Hu; Qizhong Fan; Guoxiu Han; Guojian Ding; Tingliang Fu; Lei Geng; Hongshan Yin
Journal:  Front Surg       Date:  2022-09-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.