Literature DB >> 20823042

Impact of variant pulmonary vein anatomy and image integration on long-term outcome after catheter ablation for atrial fibrillation.

Ross J Hunter1, Matthew Ginks, Richard Ang, Ihab Diab, Farai C Goromonzi, Stephen Page, Victoria Baker, Laura Richmond, Muzahir Tayebjee, Simon Sporton, Mark J Earley, Richard J Schilling.   

Abstract

AIMS: To investigate the impact of variant pulmonary vein (PV) anatomy and the use of three-dimensional image integration (3D-II) on long-term efficacy of catheter ablation for atrial fibrillation (AF).
METHODS: Consecutive procedures from 2002 to 2007 were analysed from a prospective database. All patients underwent wide area circumferential ablation, with linear lesions added and complex fractionated electrograms targeted for persistent AF. Imaging was segmented on Carto to assess PV anatomy.
RESULTS: Three hundred and fifty patients underwent 1.9 ± 0.9 procedures. The mean age was 57 ± 11 years, 73% males, and 55% paroxysmal AF. Freedom from AF/atrial tachycardia was 42% for paroxysmal AF and 20% for persistent AF at 3.1 years after the first procedure, or 86 and 66%, respectively, at 2.5 years after the last procedure. The Kaplan-Meier analysis showed a trend towards improved single-procedure efficacy with 3D-II (8.9% difference, P = 0.087) and a reduction in the number of procedures per patient from 2.1 ± 1.1 to 1.8 ± 0.9 (P < 0.0001). The use of 3D-II improved single-procedure efficacy with Carto (13.3% difference, P = 0.018), but not with Ensite NavX. Variant PV anatomy was identified in 28% and was associated with a lower single-procedure efficacy (10.0% difference, P = 0.024) but with no effect on final outcome. Multivariate analysis confirmed the impact of 3D-II [hazard ratio (HR) for recurrence of AF 0.67, P = 0.020] and variant PV anatomy (HR 1.37, P = 0.044).
CONCLUSION: The use of 3D-II improves single-procedure efficacy of PV isolation for AF. Variant PV anatomy was associated with a lower single-procedure success rate.

Entities:  

Mesh:

Year:  2010        PMID: 20823042     DOI: 10.1093/europace/euq322

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  18 in total

Review 1.  Fusion of imaging technologies: how, when, and for whom?

Authors:  Ashul Govil; Hugh Calkins; David D Spragg
Journal:  J Interv Card Electrophysiol       Date:  2011-10-01       Impact factor: 1.900

Review 2.  Radiation exposure and safety for the electrophysiologist.

Authors:  Sabine Ernst; Isabel Castellano
Journal:  Curr Cardiol Rep       Date:  2013-10       Impact factor: 2.931

3.  Accuracy of left atrial anatomical maps acquired with a multielectrode catheter during catheter ablation for atrial fibrillation.

Authors:  Jacob S Koruth; E Kevin Heist; Stephan Danik; Conor D Barrett; Rajesh Kabra; Dan Blendea; Jeremy Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2011-04-19       Impact factor: 1.900

Review 4.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 5.  Role of Cardiac Imaging (CT/MR) Before and After RF Catheter Ablation in Patients with Atrial Fibrillation.

Authors:  Aravindan Kolandaivelu
Journal:  J Atr Fibrillation       Date:  2012-08-20

6.  Impact of preprocedural imaging on outcomes of catheter ablation in patients with atrial fibrillation.

Authors:  Miki Yokokawa; Hilal Olgun; Baskaran Sundaram; Aman Chugh; Rakesh Latchamsetty; Eric Good; Thomas Crawford; Krit Jongnarangsin; Frank Pelosi; Frank Bogun; Fred Morady; Hakan Oral
Journal:  J Interv Card Electrophysiol       Date:  2012-02-23       Impact factor: 1.900

7.  Spatial torsion of the ipsilateral superior and inferior pulmonary veins.

Authors:  Songwen Chen; Xiaofeng Lu; Ya Zhen; Ying Zhuge; Feng Zhang; Gang Chen; Weidong Meng; Yiwen Yan; Shaowen Liu
Journal:  J Interv Card Electrophysiol       Date:  2013-02-07       Impact factor: 1.900

8.  Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation.

Authors:  Shang-Wei Huang; Qi Jin; Ning Zhang; Tian-You Ling; Wen-Qi Pan; Chang-Jian Lin; Qing-Zhi Luo; Yan-Xin Han; Li-Qun Wu
Journal:  Curr Med Sci       Date:  2018-04-30

9.  Does merged three-dimensional mapping improve contact force and long-term procedure outcome in atrial fibrillation ablation? (MICRO-AF study): a prospective randomized controlled study.

Authors:  Dong Geum Shin; Seung Young Roh; Jinhee Ahn; Sang Weon Park; Dong-Hyeok Kim; Sang-Jin Han; Hong Euy Lim
Journal:  Int J Cardiovasc Imaging       Date:  2021-07-13       Impact factor: 2.357

10.  A randomised comparison of Cartomerge vs. NavX fusion in the catheter ablation of atrial fibrillation: the CAVERN Trial.

Authors:  Malcolm C Finlay; Ross J Hunter; Victoria Baker; Laura Richmond; Farai Goromonzi; Glyn Thomas; Kim Rajappan; Edward Duncan; Muzahir Tayebjee; Mehul Dhinoja; Simon Sporton; Mark J Earley; Richard J Schilling
Journal:  J Interv Card Electrophysiol       Date:  2011-11-26       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.