Literature DB >> 20822830

Significant reduction of laboratory specimen labeling errors by implementation of an electronic ordering system paired with a bar-code specimen labeling process.

Peter M Hill1, Darren Mareiniss, Paula Murphy, Heather Gardner, Yu-Hsiang Hsieh, Frederick Levy, Gabor D Kelen.   

Abstract

STUDY
OBJECTIVE: We measure the rate of emergency department (ED) specimen processing error reduction after implementation of an electronic physician order entry system paired with a bar-coded specimen labeling process.
METHODS: A cohort pre- and postintervention study was conducted in the ED during a 61-month period ending September 2008 in a large urban teaching hospital. Historically, laboratory order and requisition processing was done by hand. Interventions included implementing an ED-specific electronic documentation and information system, which included physician order entry with patient verification through bar-coded wristbands and bar-coded specimen labels. The main outcome measure was processing error rate, defined as unlabeled/mislabeled/wrong patient specimen or requisition. Pre- and postimplementation data were tabulated monthly and compared in aggregate by χ(2) test. The contribution of ED error to total institution specimen error was also calculated.
RESULTS: Of the 724,465 specimens collected preintervention, 3,007 (0.42%) were recorded as errors versus 379 errors (0.11%) of 334,039 specimens collected postintervention, which represents a 74% relative and 0.31% absolute decrease (95% confidence interval 0.28% to 0.32%). The proportion of institutional errors contributed by the ED was reduced from 20.4% to 11.4%, a 44% relative and 9.0% absolute reduction (95% confidence interval 7.7% to 10.3%). Subanalysis revealed that the majority of continued errors occur when the physician order entry/bar-code system could not be used (eg, blood bank or surgical pathology specimens).
CONCLUSION: Combining an electronic physician order entry with bar-coded patient verification and electronic documentation and information system-generated specimen labels can significantly reduce ED specimen-related errors, with sizable influence on institutional specimen-related errors. Continued use of hand labeling and processing for special specimens appears inadvisable, though the cost-effectiveness of this intervention has not been established.
Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20822830     DOI: 10.1016/j.annemergmed.2010.05.028

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  3 in total

Review 1.  Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: a Laboratory Medicine Best Practices systematic review and meta-analysis.

Authors:  Susan R Snyder; Alessandra M Favoretto; James H Derzon; Robert H Christenson; Stephen E Kahn; Colleen S Shaw; Rich Ann Baetz; Diana Mass; Corinne R Fantz; Stephen S Raab; Milenko J Tanasijevic; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-06-28       Impact factor: 3.281

2.  The Information Technology Infrastructure for the Translational Genomics Core and the Partners Biobank at Partners Personalized Medicine.

Authors:  Natalie Boutin; Ana Holzbach; Lisa Mahanta; Jackie Aldama; Xander Cerretani; Kevin Embree; Irene Leon; Neeta Rathi; Matilde Vickers
Journal:  J Pers Med       Date:  2016-01-21

3.  Reduction in Hospital-Wide Clinical Laboratory Specimen Identification Errors following Process Interventions: A 10-Year Retrospective Observational Study.

Authors:  Hsiao-Chen Ning; Chia-Ni Lin; Daniel Tsun-Yee Chiu; Yung-Ta Chang; Chiao-Ni Wen; Shu-Yu Peng; Tsung-Lan Chu; Hsin-Ming Yu; Tsu-Lan Wu
Journal:  PLoS One       Date:  2016-08-05       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.