Literature DB >> 20820486

High-speed RNA microextraction technology using magnetic oligo-dT beads and lateral magnetophoresis.

Hwanyong Lee1, Jinhee Jung, Song-I Han, Ki-Ho Han.   

Abstract

This paper presents a high-speed RNA microextractor for the direct isolation of RNA from peripheral blood lysate using magnetic oligo-dT beads. The extraction is achieved through lateral magnetophoresis, generated by a ferromagnetic wire array inlaid on a glass substrate. This RNA microextractor separated more than 80% of magnetic beads with a flow rate up to 20 ml h(-1), and the overall extraction procedure was completed within 1 min. The absorbance ratio of RNA to protein (A(260)/A(280)) was >1.7, indicating that the extraction technology yielded nearly pure RNA. The feasibility of this technique was evaluated further for its applicability to reverse transcription polymerase chain reaction (RT-PCR) procedures by performing cDNA synthesis and PCR. The analysis verified that the RNA microextractor is a practical method for easy, rapid, and high-precision RT-PCR using minimal reagent volumes without requiring highly trained personnel. In addition, it can be readily incorporated into genetic analysis procedures for realizing automated on-chip genetic platforms in a micro format.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20820486     DOI: 10.1039/c005145d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  6 in total

1.  Shrink-induced sorting using integrated nanoscale magnetic traps.

Authors:  Dharmakeerthi Nawarathna; Nazila Norouzi; Jolie McLane; Himanshu Sharma; Nicholas Sharac; Ted Grant; Aaron Chen; Scott Strayer; Regina Ragan; Michelle Khine
Journal:  Appl Phys Lett       Date:  2013-02-13       Impact factor: 3.791

2.  On-chip magnetic separation and encapsulation of cells in droplets.

Authors:  Aaron Chen; Tom Byvank; Woo-Jin Chang; Atul Bharde; Greg Vieira; Brandon L Miller; Jeffrey J Chalmers; Rashid Bashir; Ratnasingham Sooryakumar
Journal:  Lab Chip       Date:  2013-03-21       Impact factor: 6.799

3.  Track-etched magnetic micropores for immunomagnetic isolation of pathogens.

Authors:  Melaku Muluneh; Wu Shang; David Issadore
Journal:  Adv Healthc Mater       Date:  2014-02-17       Impact factor: 9.933

4.  Nanotechnology for the detection and kill of circulating tumor cells.

Authors:  Yang Gao; Zhou Yuan
Journal:  Nanoscale Res Lett       Date:  2014-09-15       Impact factor: 4.703

5.  Parallel RNA extraction using magnetic beads and a droplet array.

Authors:  Xu Shi; Chun-Hong Chen; Weimin Gao; Shih-Hui Chao; Deirdre R Meldrum
Journal:  Lab Chip       Date:  2015-02-21       Impact factor: 6.799

Review 6.  Diagnostic strategies for SARS-CoV-2 infection and interpretation of microbiological results.

Authors:  G Caruana; A Croxatto; A T Coste; O Opota; F Lamoth; K Jaton; G Greub
Journal:  Clin Microbiol Infect       Date:  2020-06-25       Impact factor: 8.067

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.