Literature DB >> 20819588

Comparative study of 4Fr catheters using the ACIST variable rate injector system versus 6Fr catheters using hand manifold in diagnostic coronary angiography via transradial approach.

Lei Hou1, Yi-dong Wei, Jing Song, Wen-liang Che, Wen-hui Peng, Yong Wang, Wei-ming Li, Ya-wei Xu, Da-yi Hu.   

Abstract

BACKGROUND: The transradial approach is regarded as a useful vascular site for coronary procedures. The aim of this study was to test whether 4Fr catheters assisted by ACIST variable rate injector system can produce comparable angiographic quality and reduce the risk of radial artery injury compared to hand manifold 6 Fr catheters.
METHODS: A total of 1816 patients were studied consecutively, among whom 856 patients received coronary angiography by 4 Fr catheters (4Fr group) and 960 patients by 6 Fr catheters (6Fr group). Angiographic and procedural characteristics were observed and recorded. The luminal inner radial arterial diameter before and after the procedure were collected.
RESULTS: The baseline clinical characteristics were similar in both groups. There were no significant differences in procedure time, radiation dose and quality scores in both groups (P > 0.05), but more contrast media was delivered in the 6Fr group (P < 0.001). The mean radial arterial diameter six months after the procedure in the 6Fr group reduced significantly compared to that measured one day prior to the procedure (P < 0.001).
CONCLUSIONS: Coronary angiography using the 4Fr catheters with Acist power injection system can achieve an acceptable diagnostic quality while at the same time minimizing radial artery injury and contrast media consumption.

Entities:  

Mesh:

Year:  2010        PMID: 20819588

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  2 in total

Review 1.  Meta-analysis of the effect of automated contrast injection devices versus manual injection and contrast volume on risk of contrast-induced nephropathy.

Authors:  Kristopher D Minsinger; Hayah M Kassis; Clay A Block; Mandeep Sidhu; Jeremiah R Brown
Journal:  Am J Cardiol       Date:  2013-10-03       Impact factor: 2.778

Review 2.  Clinical and Procedural Outcomes of 5-French versus 6-French Sheaths in Transradial Coronary Interventions.

Authors:  Alberto Polimeni; Francesco Passafaro; Salvatore De Rosa; Sabato Sorrentino; Daniele Torella; Carmen Spaccarotella; Annalisa Mongiardo; Ciro Indolfi
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.