Literature DB >> 20818799

A rapid screening LC-MS/MS method based on conventional HPLC pumps for the analysis of low molecular weight xenobiotics: application to doping control analysis.

Monica Mazzarino1, Xavier de la Torre, Francesco Botrè, Nicola Gray, David Cowan.   

Abstract

This study presents a fast multi-analyte screening method specifically developed for the detection of xenobiotics in urine. The proposed method allows the screening of several classes of substance in a single chromatographic method with a run-time of 11 min, inclusive of post-run and reconditioning times. Chromatographic separation is achieved in 7.2 min using a reversed-phase 2.7 µm fused-core particle column, generating a back-pressure not exceeding 400 bar and therefore enabling the use of traditional high performance liquid chromatography (HPLC) instruments. The effectiveness of this approach was evaluated, by liquid-chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization, using 20 blank urine samples spiked with 45 compounds prohibited in sport: 11 diuretics, 16 glucocorticoids, 9 stimulants, 5 anti-oestrogens, as well as formoterol, carboxy-finasteride (previously prohibited by the World Anti-Doping Agency (WADA) in 2008), gestrinone and tetrahydrogestrinone. Qualitative validation shows the proposed method to be specific with no significant interference. All of the analytes considered in this study were clearly distinguishable in urine, with limits of detection ranging from 5 ng/mL to 350 ng/mL, significantly below the Minimum Required Performance Levels (MRPL) set by WADA for the accredited sports anti-doping laboratories. All compounds of interest were separated, including synthetic and endogenous glucocorticoids with similar retention times and fragmentation patterns. Copyright 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20818799     DOI: 10.1002/dta.148

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  2 in total

1.  Application of LC-MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids.

Authors:  Jamshed Haneef; Mohammad Shaharyar; Asif Husain; Mohd Rashid; Ravinesh Mishra; Shama Parveen; Niyaz Ahmed; Manoj Pal; Deepak Kumar
Journal:  J Pharm Anal       Date:  2013-04-02

2.  The Usefulness of MS3 to Confirm Poisoning on the Example of Dog Poisoning with Strychnine.

Authors:  Tomasz Śniegocki; Bartosz Sell; Andrzej Posyniak
Journal:  Molecules       Date:  2019-10-19       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.