Literature DB >> 20818281

Interactions of lens care with silicone hydrogel lenses and effect on comfort.

Mark D P Willcox1, Bronwen Phillips, Jerome Ozkan, Isabelle Jalbert, Laurence Meagher, Thomas Gengenbach, Brien Holden, Eric Papas.   

Abstract

PURPOSE: The purpose of this study was to investigate the effect of lens care products on short-term subjective and physiological performance silicone hydrogel lenses.
METHODS: Ten subjects wore either lotrafilcon B or galyfilcon A silicone hydrogel contact lenses soaked in a lens care product containing either Polyquad/Aldox or PHMB or control lenses inserted directly from the pack. Subjects wore the lenses for 6 h. Ocular comfort (graded on a 1 to 10 scale) and ocular physiology were assessed. Unworn but soaked lenses were analyzed for metrological changes, release of excipients into phosphate buffered saline, and changes to their surface chemical composition.
RESULTS: None of the lens metrology measures or clinically observed conjunctival or limbal redness changed. Corneal staining was significantly (p < 0.008) raised, albeit to low levels, after 6 h wear for either lens type when soaked in the PHMB solution compared with the control lens (lotrafilcon B 0.4 to 0.9 ± 0.7 to 0.4 vs. 0.1 to 0.4 ± 0.3 to 0.5; galyfilcon A 0.2 to 0.3 ± 0.2 to 0.4 vs. 0.0 ± 0.0). For lotrafilcon B lenses, there were decreases in comfort (p = 0.002), increases in burning/stinging (p = 0.002) after 1 h of wear, and increases in lens awareness on lens insertion (p = 0.0001) when soaked in PHMB. However, lotrafilcon B lenses soaked in Polyquad/Aldox showed increases in burning/stinging after 1 and 6 h (p < 0.008) of lens wear. For galyfilcon A lenses, most significant (p ≤ 0.002) changes to symptomatology occurred after soaking in Polyquad/Aldox solution. More PHMB was released from lotrafilcon B lenses, and more MPDS material was released from galyfilcon A lenses. The surface of galyfilcon A lenses changed but irrespective of lens solution type, whereas the changes to the lens surface was dependent on solution type for lotrafilcon B lenses.
CONCLUSIONS: Lens care products can change corneal staining and comfort responses during wear. These changes may be associated with release of material soaked into lenses or changes to the lens surface composition.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20818281     DOI: 10.1097/OPX.0b013e3181f3e2fc

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

1.  The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology.

Authors:  Fiona Stapleton; Carl Marfurt; Blanka Golebiowski; Mark Rosenblatt; David Bereiter; Carolyn Begley; Darlene Dartt; Juana Gallar; Carlos Belmonte; Pedram Hamrah; Mark Willcox
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-18       Impact factor: 4.799

2.  Comparison of the effects of different lens-cleaning solutions on the protein profiles of human conjunctival cells.

Authors:  Katharina Bell; Ewa Buksinska; Norbert Pfeiffer; Franz Herman Grus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-07-22       Impact factor: 3.117

3.  Effect of contact lens material on cytotoxicity potential of multipurpose solutions using human corneal epithelial cells.

Authors:  M B Gorbet; N C Tanti; B Crockett; L Mansour; L Jones
Journal:  Mol Vis       Date:  2011-12-28       Impact factor: 2.367

4.  Ocular surface response and subjective symptoms associated to lens care solutions in Palestine.

Authors:  Ithar M Beshtawi; Jamal Qaddomi; Hanady Khuffash; Safa El-Titi; Malak Ghannam; Reema Otaibi
Journal:  J Optom       Date:  2019-07-19

5.  Quantification of individual proteins in silicone hydrogel contact lens deposits.

Authors:  Negar Babaei Omali; Zhenjun Zhao; Hua Zhu; Daniel Tilia; Mark D P Willcox
Journal:  Mol Vis       Date:  2013-02-18       Impact factor: 2.367

6.  Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.

Authors:  Nery García-Porta; Laura Rico-del-Viejo; Helena Ferreira-Neves; Sofia C Peixoto-de-Matos; Antonio Queirós; José M González-Méijome
Journal:  Biomed Res Int       Date:  2015-03-31       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.