Literature DB >> 20816247

Diagnostic accuracy of the Heidelberg Retina Tomograph for glaucoma a population-based assessment.

Paul R Healey1, Anne J Lee, Tin Aung, Tien Y Wong, Paul Mitchell.   

Abstract

OBJECTIVE: To evaluate the Heidelberg Retina Tomograph II (HRTII; Heidelberg Engineering, Heidelberg, Germany) as a screening tool for open-angle glaucoma (OAG) in an older population.
DESIGN: Population-based, cross-sectional study. PARTICIPANTS: Participants from the 10-year follow-up Blue Mountains Eye Study (n = 1952; 75.6% of survivors).
METHODS: Participants underwent optic nerve head imaging performed using the HRTII; OAG was diagnosed independently from optic disc photographs and Humphrey 24-2 visual fields. MAIN OUTCOME MEASURES: The Moorfields Regression Analysis (MRA) was applied to scans using the default results of "normal," borderline," and "outside normal limits." Outcome classification was at the person level and used data from both eyes.
RESULTS: Mean age was 73.7 years. The HRT scans could be acquired in 1644 participants, 95.9% of those fully examined; 87.4% of scans having a topography standard deviation (TSD) < or =40 microm. Larger TSD was associated with older age and OAG. The MRA sensitivity was 64.1%, specificity 85.7%, positive predictive value 21%, and negative predictive value 97.6% for detecting OAG. Including borderline results improved sensitivity (87.0%) but specificity dropped to 70.6%. Significant predictors of abnormal MRA included OAG (odds ratio [OR], 7.70; 95% confidence interval [CI] 4.79-12.35), age (OR, 1.05; 95% CI, 1.03-1.07), TSD (OR, 1.01; 95% CI, 1.003-1.020) and disc size (OR, 3.2; 95% CI, 2.31-4.49). Diagnostic accuracy was improved by restricting TSD <40 microm. Further TSD restriction improved specificity at the expense of sensitivity. As disc size increased, specificity fell whereas sensitivity, OAG prevalence, and the proportion testing positive rose. Glaucoma prevalence, positive predictive value, and the proportion testing positive increased, but specificity fell with increasing age. Sensitivity also fell between youngest and oldest groups. Diagnostic performance improved for visual field mean deviation < -4.0 dB. Single eye analyses overestimated specificity and underestimated sensitivity compared with using data from both eyes.
CONCLUSIONS: Diagnostic test evaluation studies of HRTII using single eye analyses or restrictive selection overestimate test accuracy compared with this population-based study. Although the specificity of the MRA was inadequate for use as a glaucoma screening test, the HRTII performed relatively well in an unselected older population with acceptable quality scans in most eyes.
Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20816247     DOI: 10.1016/j.ophtha.2010.07.001

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  10 in total

1.  Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension.

Authors:  Christos Pitsas; Dimitrios Papaconstantinou; Ilias Georgalas; Ioannis Halkiadakis
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Population-based evaluation of retinal nerve fiber layer, retinal ganglion cell layer, and inner plexiform layer as a diagnostic tool for glaucoma.

Authors:  Henriët Springelkamp; Kyungmoo Lee; Roger C W Wolfs; Gabriëlle H S Buitendijk; Wishal D Ramdas; Albert Hofman; Johannes R Vingerling; Caroline C W Klaver; Michael D Abràmoff; Nomdo M Jansonius
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-11-20       Impact factor: 4.799

3.  Crowdsourcing to Evaluate Fundus Photographs for the Presence of Glaucoma.

Authors:  Xueyang Wang; Lucy I Mudie; Mani Baskaran; Ching-Yu Cheng; Wallace L Alward; David S Friedman; Christopher J Brady
Journal:  J Glaucoma       Date:  2017-06       Impact factor: 2.503

4.  Predictive value of screening tests for visually significant eye disease.

Authors:  Laura J Kopplin; Steven L Mansberger
Journal:  Am J Ophthalmol       Date:  2015-06-04       Impact factor: 5.258

5.  Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter.

Authors:  Balwantray C Chauhan; Neil O'Leary; Faisal A AlMobarak; Alexandre S C Reis; Hongli Yang; Glen P Sharpe; Donna M Hutchison; Marcelo T Nicolela; Claude F Burgoyne
Journal:  Ophthalmology       Date:  2012-12-23       Impact factor: 12.079

6.  HRT for the Diagnosis and Detection of Glaucoma Progression.

Authors:  Jessica S Maslin; Kaweh Mansouri; Syril K Dorairaj
Journal:  Open Ophthalmol J       Date:  2015-05-15

7.  Corneal Segmentation Analysis Increases Glaucoma Diagnostic Ability of Optic Nerve Head Examination, Heidelberg Retina Tomograph's Moorfield's Regression Analysis, and Glaucoma Probability Score.

Authors:  F Saenz-Frances; L Jañez; C Berrozpe-Villabona; L Borrego-Sanz; L Morales-Fernández; A Acebal-Montero; C D Mendez-Hernandez; J M Martinez-de-la-Casa; E Santos-Bueso; J Garcia-Sanchez; J Garcia-Feijoo
Journal:  J Ophthalmol       Date:  2015-05-27       Impact factor: 1.909

8.  Utility of Heidelberg retinal tomography as a screening tool for analyzing retinal nerve fiber layer defects.

Authors:  David A Belyea; Rashed N Alhabshan; Sankaranarayana P Mahesh; Gregory S Gertner; Mirsad M Ibisevic; Abdullah S Habib; Jacob A Dan
Journal:  Clin Ophthalmol       Date:  2014-11-28

9.  Diagnostic accuracy of macular ganglion cell-inner plexiform layer thickness for glaucoma detection in a population-based study: Comparison with optic nerve head imaging parameters.

Authors:  Victor Koh; Yih-Chung Tham; Carol Y Cheung; Baskaran Mani; Tien Yin Wong; Tin Aung; Ching-Yu Cheng
Journal:  PLoS One       Date:  2018-06-26       Impact factor: 3.240

10.  Association of open-angle glaucoma loci with incident glaucoma in the Blue Mountains Eye Study.

Authors:  Kathryn P Burdon; Paul Mitchell; Anne Lee; Paul R Healey; Andrew J R White; Elena Rochtchina; Peter B M Thomas; Jie Jin Wang; Jamie E Craig
Journal:  Am J Ophthalmol       Date:  2014-09-19       Impact factor: 5.258

  10 in total