Literature DB >> 20815651

Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation.

Jonathan J Elsner1, Sigal Portnoy, Gal Zur, Farshid Guilak, Avi Shterling, Eran Linder-Ganz.   

Abstract

The development of a synthetic meniscal implant that does not require surgical attachment but still provides the biomechanical function necessary for joint preservation would have important advantages. We present a computational-experimental approach for the design optimization of a free-floating polycarbonate-urethane (PCU) meniscal implant. Validated 3D finite element (FE) models of the knee and PCU-based implant were analyzed under physiological loads. The model was validated by comparing calculated pressures, determined from FE analysis to tibial plateau contact pressures measured in a cadaveric knee in vitro. Several models of the implant, some including embedded reinforcement fibers, were tested. An optimal implant configuration was then selected based on the ability to restore pressure distribution in the knee, manufacturability, and long-term safety. The optimal implant design entailed a PCU meniscus embedded with circumferential reinforcement made of polyethylene fibers. This selected design can be manufactured in various sizes, without risking its integrity under joint loads. Importantly, it produces an optimal pressure distribution, similar in shape and values to that of natural meniscus. We have shown that a fiber-reinforced, free-floating PCU meniscal implant can redistribute joint loads in a similar pattern to natural meniscus, without risking the integrity of the implant materials.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20815651     DOI: 10.1115/1.4001892

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  19 in total

Review 1.  Synthetic meniscus replacement: a review.

Authors:  Anne Christiane Theodora Vrancken; Pieter Buma; Tony George van Tienen
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

Review 2.  Treatment options for the symptomatic post-meniscectomy knee.

Authors:  Matej Drobnič; Ersin Ercin; Joao Gamelas; Emmanuel T Papacostas; Konrad Slynarski; Urszula Zdanowicz; Tim Spalding; Peter Verdonk
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-03-11       Impact factor: 4.342

Review 3.  The role of meniscal tissue in joint protection in early osteoarthritis.

Authors:  Rene Verdonk; Henning Madry; Nogah Shabshin; Florian Dirisamer; Giuseppe M Peretti; Nicolas Pujol; Tim Spalding; Peter Verdonk; Romain Seil; Vincenzo Condello; Berardo Di Matteo; Johannes Zellner; Peter Angele
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-16       Impact factor: 4.342

4.  A Hydrogel Meniscal Replacement: Knee Joint Pressure and Distribution in an Ovine Model Compared to Native Tissue.

Authors:  Kristine M Fischenich; Hannah M Pauly; Jackson T Lewis; Travis S Bailey; Tammy L Haut Donahue
Journal:  Ann Biomed Eng       Date:  2018-06-19       Impact factor: 3.934

5.  Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement.

Authors:  Kristine M Fischenich; Katie Boncella; Jackson T Lewis; Travis S Bailey; Tammy L Haut Donahue
Journal:  J Biomed Mater Res A       Date:  2017-06-27       Impact factor: 4.396

Review 6.  Current Concepts in Meniscus Tissue Engineering and Repair.

Authors:  Bahar Bilgen; Chathuraka T Jayasuriya; Brett D Owens
Journal:  Adv Healthc Mater       Date:  2018-03-15       Impact factor: 9.933

7.  A statistically-augmented computational platform for evaluating meniscal function.

Authors:  Hongqiang Guo; Thomas J Santner; Tony Chen; Hongsheng Wang; Caroline Brial; Susannah L Gilbert; Matthew F Koff; Amy L Lerner; Suzanne A Maher
Journal:  J Biomech       Date:  2015-02-26       Impact factor: 2.712

8.  Organized nanofibrous scaffolds that mimic the macroscopic and microscopic architecture of the knee meniscus.

Authors:  Matthew B Fisher; Elizabeth A Henning; Nicole Söegaard; John L Esterhai; Robert L Mauck
Journal:  Acta Biomater       Date:  2012-10-22       Impact factor: 8.947

9.  Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model.

Authors:  A C T Vrancken; W Madej; G Hannink; N Verdonschot; T G van Tienen; P Buma
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

10.  Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.

Authors:  Duraisamy Shriram; Gideon Praveen Kumar; Fangsen Cui; Yee Han Dave Lee; Karupppasamy Subburaj
Journal:  Sci Rep       Date:  2017-07-20       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.