Literature DB >> 20815063

Interobserver and intraobserver variability of the apparent diffusion coefficient in treated malignant hepatic lesions on a 3.0T machine: measurements in the whole lesion versus in the area with the most restricted diffusion.

Tri-Linh C Lu1, Reto A Meuli, Pedro M Marques-Vidal, Pierre Bize, Alban Denys, Sabine Schmidt.   

Abstract

PURPOSE: To assess the inter/intraobserver variability of apparent diffusion coefficient (ADC) measurements in treated hepatic lesions and to compare ADC measurements in the whole lesion and in the area with the most restricted diffusion (MRDA).
MATERIALS AND METHODS: Twenty-five patients with treated malignant liver lesions were examined on a 3.0T machine. After agreeing on the best ADC image, two readers independently measured the ADC values in the whole lesion and in the MRDA. These measurements were repeated 1 month later. The Bland-Altman method, Spearman correlation coefficients, and the Wilcoxon signed-rank test were used to evaluate the measurements.
RESULTS: Interobserver variability for ADC measurements in the whole lesion and in the MRDA was 0.17 x 10(-3) mm(2)/s [-0.17, +0.17] and 0.43 x 10(-3) mm(2)/s [-0.45, +0.41], respectively. Intraobserver limits of agreement could be as low as [-0.10, +0.12] 10(-3) mm(2)/s and [-0.20, +0.33] 10(-3) mm(2)/s for measurements in the whole lesion and in the MRDA, respectively.
CONCLUSION: A limited variability in ADC measurements does exist, and it should be considered when interpreting ADC values of hepatic malignancies. This is especially true for the measurements of the minimal ADC.

Entities:  

Mesh:

Year:  2010        PMID: 20815063     DOI: 10.1002/jmri.22301

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Interobserver agreement of semi-automated and manual measurements of functional MRI metrics of treatment response in hepatocellular carcinoma.

Authors:  David Bonekamp; Susanne Bonekamp; Vivek Gowdra Halappa; Jean-Francois H Geschwind; John Eng; Celia Pamela Corona-Villalobos; Timothy M Pawlik; Ihab R Kamel
Journal:  Eur J Radiol       Date:  2013-12-03       Impact factor: 3.528

2.  Evolution of multi-parametric MRI quantitative parameters following transrectal ultrasound-guided biopsy of the prostate.

Authors:  A Latifoltojar; N Dikaios; A Ridout; C Moore; R Illing; A Kirkham; S Taylor; S Halligan; D Atkinson; C Allen; M Emberton; S Punwani
Journal:  Prostate Cancer Prostatic Dis       Date:  2015-07-21       Impact factor: 5.554

3.  Apparent diffusion coefficient values in Modic changes - interobserver reproducibility and relation to Modic type.

Authors:  Magnhild H Dagestad; Nils Vetti; Per M Kristoffersen; John-Anker Zwart; Kjersti Storheim; Gunnstein Bakland; Jens I Brox; Lars Grøvle; Gunn H Marchand; Erling Andersen; Jörg Assmus; Ansgar Espeland
Journal:  BMC Musculoskelet Disord       Date:  2022-07-22       Impact factor: 2.562

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.