Literature DB >> 20815060

Multiple-bolus dynamic contrast-enhanced MRI in the pancreas during a glucose challenge.

J H Naish1, C E Hutchinson, A Caunce, C Roberts, J C Waterton, P D Hockings, C J Taylor, G J M Parker.   

Abstract

PURPOSE: To assess the feasibility of multiple-bolus dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in the pancreas; to optimize the analysis; and to investigate application of the method to a glucose challenge in type 2 diabetes.
MATERIALS AND METHODS: A 4-bolus DCE-MRI protocol was performed on five patients with type 2 diabetes and 11 healthy volunteers during free-breathing. Motion during the dynamic time series was corrected for using a model-driven nonlinear registration. A glucose challenge was administered intravenously between the first and second DCE-MRI acquisition in all patients and in seven of the healthy controls.
RESULTS: Image registration improved the reproducibility of the DCE-MRI model parameters across the repeated bolus-acquisitions in the healthy controls with no glucose challenge (eg, coefficient of variation for K(trans) improved from 38% to 28%). Native tissue T(1) was significantly lower in patients (374 +/- 68 msec) compared with volunteers (519 +/- 41 msec) but there was no significant difference in any of the baseline DCE-MRI parameters. No effect of glucose challenge was observed in either the patients or healthy volunteers.
CONCLUSION: Multiple bolus DCE-MRI is feasible in the pancreas and is improved by nonlinear image registration but is not sensitive to the effects of an intravenous glucose challenge.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20815060     DOI: 10.1002/jmri.22281

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Empirical mathematical model for dynamic manganese-enhanced MRI of the murine pancreas for assessment of β-cell function.

Authors:  Anita H Dhyani; Xiaobing Fan; Lara Leoni; Muhammad Haque; Brian B Roman
Journal:  Magn Reson Imaging       Date:  2012-10-25       Impact factor: 2.546

2.  Feasibility of test-bolus DCE-MRI using CAIPIRINHA-VIBE for the evaluation of pancreatic malignancies.

Authors:  Jimi Huh; Yoonseok Choi; Dong-Cheol Woo; Nieun Seo; Bohyun Kim; Chang Kyung Lee; In Seong Kim; Dominik Nickel; Kyung Won Kim
Journal:  Eur Radiol       Date:  2016-01-25       Impact factor: 5.315

Review 3.  Quantitative Magnetic Resonance Imaging of the Pancreas of Individuals With Diabetes.

Authors:  John Virostko
Journal:  Front Endocrinol (Lausanne)       Date:  2020-12-04       Impact factor: 5.555

4.  Six-dimensional quantitative DCE MR Multitasking of the entire abdomen: Method and application to pancreatic ductal adenocarcinoma.

Authors:  Nan Wang; Srinivas Gaddam; Lixia Wang; Yibin Xie; Zhaoyang Fan; Wensha Yang; Richard Tuli; Simon Lo; Andrew Hendifar; Stephen Pandol; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2020-01-21       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.