Literature DB >> 20814877

Accuracy of fetal gender determination in the first trimester using three-dimensional ultrasound.

A Youssef1, T Arcangeli, D Radico, E Contro, F Guasina, F Bellussi, E Maroni, A M Morselli-Labate, A Farina, G Pilu, G Pelusi, T Ghi.   

Abstract

OBJECTIVES: To evaluate the accuracy of three-dimensional (3D) ultrasound in fetal gender assignment in the first trimester.
METHODS: A series of pregnant women attending at 11 to 13 + 6 weeks for the nuchal translucency (NT) scan were enrolled into the study. An ultrasound volume of each fetus was obtained and stored for offline analysis. On the reconstructed mid-sagittal plane, the angle between the genital tubercle and an imaginary line passing tangentially through the fetal back (genital angle) was estimated and a receiver-operating characteristics (ROC) curve was constructed to determine the best cut-off for genital angle in fetal male gender determination. Fetal gender was subsequently ascertained in all cases. To calculate the interobserver variability, a second operator repeated the measurements.
RESULTS: There were 85 cases included in the study. The genital angle in males was significantly higher than that in females (51.2 ± 11.3° (n = 36) vs. 18.9 ± 4.1 (n = 49), P < 0.001). The ROC curve revealed the estimated genital angle to have a high degree of accuracy in fetal gender determination (area under the curve ± SE = 1.000 ± 0.001). The best cut-off for male gender determination was found to be between 27° and 29° (sensitivity, 100%; specificity, 98.0%). There was a high degree of correlation between the two operators (r(2) = 0.998; coefficient of variation = 5.4%).
CONCLUSIONS: 3D ultrasound is a highly accurate and reproducible tool for fetal gender assignment prior to 14 weeks of gestation.
Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 20814877     DOI: 10.1002/uog.8812

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  Accuracy of sonographic fetal gender determination: predictions made by sonographers during routine obstetric ultrasound scans.

Authors:  Manette Kearin; Karen Pollard; Ian Garbett
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

2.  Comparison of two-dimensional (2D) and three-dimensional (3D) ultrasonography for gestational ageing in the early to mid-pregnant bitch.

Authors:  Sabina Pestelacci; Nikolaos Tzanidakis; Iris Margaret Reichler; Orsolya Balogh
Journal:  Reprod Domest Anim       Date:  2021-11-25       Impact factor: 1.858

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.