Literature DB >> 20814694

Determination of absolute size of fundus objects.

Jens Dawczynski1, Michael Gebhardt, Thomas Mohr, Ingo Koschmieder, Bernhard Rassow, Anne-Kathrin Schubert, Jürgen Strobel.   

Abstract

BACKGROUND: Creating multiple beam interference fringes on the retina using the "retina fringe projector" (RFP) provides us with a scale which can be used to determine the absolute size of objects at the fundus.
METHODS: The procedure is tested on an model eye, the optical parameters of which are varied in order to simulate different refraction conditions. The RFP was used to determine the size of a known object at the model fundus; the result was then checked against the real value of the object. In a second series of measurements, the RFP fringes were included in fundus photos of 52 patients with varying levels of ametropia, taken at the University Eye Clinic in Jena using the FF450 fundus camera (manufacturer: Carl Zeiss Meditec AG) for diagnostic purposes. The distance between the fringes was determined using both the RFP and the Littmann method.
RESULTS: The differences to the real value of the fundus size of a known object deviated on average by 1 to 2%, and always remained under 3% in the model eye. A very good correlation between RFP and Littmann methods results could be found in the clinical part of the study. The resulting deviations are below 2.5%.
CONCLUSION: Integration of a RFP in a fundus camera permits measurement of absolute values of the retina, regardless of the type of observation or documentation. Knowing the real size of fundus objects holds a potential in many clinical classification scales of fundus objects such as drusen or vessels, or in optimizing photodynamic therapy spot size measurement.

Entities:  

Mesh:

Year:  2010        PMID: 20814694     DOI: 10.1007/s00417-010-1498-3

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  14 in total

1.  Correction of optic disc measurements on fundus photographs.

Authors:  B Bengtsson; C E Krakau
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

Review 2.  An appraisal of the accuracy of Littmann's method of determining the real dimension of a retinal object.

Authors:  D B Barr
Journal:  Acta Ophthalmol Scand Suppl       Date:  1995

3.  A method of determining the equivalent powers of the eye and its crystalline lens without resort to phakometry.

Authors:  A G Bennett
Journal:  Ophthalmic Physiol Opt       Date:  1988       Impact factor: 3.117

4.  Absolute ocular fundus dimensions measured by multiple-beam interference fringes.

Authors:  P Baumbach; B Rassow; W Wesemann
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-11       Impact factor: 4.799

5.  Image size in the fundus: structural evidence for wide-field retinal magnification factor.

Authors:  A L Holden; F W Fitzke
Journal:  Br J Ophthalmol       Date:  1988-03       Impact factor: 4.638

6.  [Experiences with the laser-interference stripe test for the measurement of retinal resolution capacity].

Authors:  B Rassow; D Wolf
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1973-04-07

7.  Improvements on Littmann's method of determining the size of retinal features by fundus photography.

Authors:  A G Bennett; A R Rudnicka; D F Edgar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-06       Impact factor: 3.117

8.  [Determination of the real size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-04       Impact factor: 0.700

9.  Optical and retinal factors affecting visual resolution.

Authors:  F W Campbell; D G Green
Journal:  J Physiol       Date:  1965-12       Impact factor: 5.182

10.  Measurement of optic disc size: equivalence of methods to correct for ocular magnification.

Authors:  D F Garway-Heath; A R Rudnicka; T Lowe; P J Foster; F W Fitzke; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 5.908

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.