Effective gas exchange in paralyzed juvenile rabbits using simple, inexpensive respiratory support devices.

Robert M Diblasi1, Jay C Zignego, Charles V Smith, Thomas N Hansen, C Peter Richardson.   

Abstract

We have developed two devices: a high-amplitude bubble continuous positive airway pressure (HAB-CPAP) and an inexpensive bubble intermittent mandatory ventilator (B-IMV) to test the hypotheses that simple, inexpensive devices can provide gas exchange similar to that of bubble CPAP (B-CPAP) and conventional mechanical ventilation (CMV). Twelve paralyzed juvenile rabbits were intubated, stabilized on CMV, and then switched to CPAP. On identical mean airway pressures (MAPs), animals were unable to maintain pulse oximeter oxygen saturation (SpO2) >80% on conventional B-CPAP, but all animals oxygenated well (97.3 ± 2.1%) on HAB-CPAP. In fact, arterial partial pressures of O2 (Pao2) were higher during HAB-CPAP than during CMV (p = 0.01). After repeated lung lavages, arterial partial pressures of CO2 (Paco2) were lower with B-IMV than with CMV (p < 0.0001), despite identical ventilator settings. In lavaged animals, when HAB-CPAP was compared with CMV at the same MAP and 100% O2, no differences were observed in Pao2, but Paco2 levels were higher with HAB-CPAP (70 ± 7 versus 50 ± 5 mm Hg; p < 0.05). Arterial blood pressures were not impaired by HAB-CPAP or B-IMV. The results confirm that simple inexpensive devices can provide respiratory support in the face of severe lung disease and could extend the use of respiratory support for preterm infants into severely resource-limited settings.

Entities:  

Mesh:

Year:  2010        PMID: 20814347     DOI: 10.1203/PDR.0b013e3181f985f0

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  5 in total

1.  Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

Authors:  Sucheta Yadav; Anu Thukral; M Jeeva Sankar; V Sreenivas; Ashok K Deorari; Vinod K Paul; Ramesh Agarwal
Journal:  Indian J Pediatr       Date:  2011-12-23       Impact factor: 1.967

Review 2.  Non-invasive Respiratory Support of the Premature Neonate: From Physics to Bench to Practice.

Authors:  Ibrahim Sammour; Sreenivas Karnati
Journal:  Front Pediatr       Date:  2020-05-08       Impact factor: 3.418

3.  A trial comparing continuous positive airway pressure (CPAP) devices in preterm infants.

Authors:  Carl H Backes; Jennifer N Cooper; Jennifer L Notestine; Crystal M Alfred; Molly K Ball; Brian K Rivera; Jane M Lamp; Laura Marzec; Michael R Stenger; Mohannad Moallem; Randy R Miller; Apurwa Naik; Lindsey J Beer; Christopher R Howard; Stephen E Welty; C Peter Richardson; Noah H Hillman; John A F Zupancic; Larissa I Stanberry; Thomas N Hansen; Charles V Smith
Journal:  J Perinatol       Date:  2020-05-20       Impact factor: 2.521

4.  Performance Characteristics of a Novel 3D-Printed Bubble Intermittent Mandatory Ventilator (B-IMV) for Adult Pulmonary Support.

Authors:  Jonathan A Poli; Christopher Howard; Alfredo J Garcia; Don Remboski; Peter B Littlewood; John P Kress; Narayanan Kasthuri; Alia Comai; Kiran Soni; Philip Kennedy; John Ogger; Robert M DiBlasi
Journal:  Bioengineering (Basel)       Date:  2022-04-02

5.  A high-value, low-cost bubble continuous positive airway pressure system for low-resource settings: technical assessment and initial case reports.

Authors:  Jocelyn Brown; Heather Machen; Kondwani Kawaza; Zondiwe Mwanza; Suzanne Iniguez; Hans Lang; Alfred Gest; Neil Kennedy; Robert Miros; Rebecca Richards-Kortum; Elizabeth Molyneux; Maria Oden
Journal:  PLoS One       Date:  2013-01-23       Impact factor: 3.240