Literature DB >> 20813490

Reduced mortality with noninvasive hemodynamic monitoring of shock.

J Steven Hata1, Corey Stotts, Constance Shelsky, Emine O Bayman, Anita Frazier, Jenny Wang, Ellen J Nickel.   

Abstract

PURPOSE: This study compared clinical outcomes associated with exposure to pulmonary artery catheters (PACs), central venous catheters (CVCs), arterial pressure waveform analysis for cardiac output (APCO), or no central monitoring (NCM) in patients with shock.
MATERIALS AND METHODS: We assessed 6929 consecutive patients from 2003 to 2006 within a surgical intensive care unit of a university hospital, identifying 237 mechanically ventilated patients with shock.
RESULTS: Adjusted for severity of illness, use of APCO monitoring, compared with other options, was associated with reduced intensive care unit mortality (odds ratio [OR], 0.37; 95% confidence interval [CI], 0.18-0.77) and 28-day mortality (OR, 0.43; 95% CI, 0.22-0.85). Other monitors were not associated with changes of 28-day mortality (CVC: OR, 0.63; 95% CI, 0.34-1.17; PAC: OR, 0.78; 95% CI, 0.36-1.69) or were associated with increased risk (NCM: OR, 2.29; 95% CI, 1.14-4.61). There were significant differences in the fluid and vasoactive drug prescriptions among the groups.
CONCLUSIONS: This study supports an association between the use of APCO monitoring and reduction in mortality in shock compared with traditional methods of monitoring. Although it is impossible to exclude the role of unrecognized/unrecorded differences among the groups, these findings may result from differences in supportive care, directed by monitor technology.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20813490     DOI: 10.1016/j.jcrc.2010.07.001

Source DB:  PubMed          Journal:  J Crit Care        ISSN: 0883-9441            Impact factor:   3.425


  2 in total

Review 1.  Using what you get: dynamic physiologic signatures of critical illness.

Authors:  Andre L Holder; Gilles Clermont
Journal:  Crit Care Clin       Date:  2015-01       Impact factor: 3.598

2.  Non-invasive cardiac output and oxygen delivery measurement in an infant with critical anemia.

Authors:  Garry M Steil; Olive S Eckstein; Julie Caplow; Michael S D Agus; Brian K Walsh; Jackson Wong
Journal:  J Clin Monit Comput       Date:  2011-06-21       Impact factor: 2.502

  2 in total