Literature DB >> 20812579

AperFix versus transfix in reconstruction of anterior cruciate ligament.

Onat Uzumcugil1, Ahmet Dogan, Erhan Dalyaman, Merter Yalcinkaya, Emre Akman, Yusuf Ozturkmen, Mustafa Caniklioglu.   

Abstract

The aim of this retrospective study was to compare clinical outcomes of the TransFix (Arthrex Inc., Naples, FL) fixation method and the brand-new AperFix (Cayenne Medical, Scottsdale, AZ) device in arthroscopic reconstruction of anterior cruciate ligament. A total of 38 patients with isolated complete anterior cruciate ligament rupture underwent arthroscopic reconstruction via two different fixation methods using hamstring autografts. Patients were evaluated in terms of range of motion values, Lysholm scores, laxity testing, and complications. Average flexion was 136.53 +/- 6.9 degrees in the TransFix group and 126.32 +/- 4.9 degrees in the AperFix group (p < 0.001). Mean Lysholm score was 82.42 +/- 8.5 in the TransFix group and 88.68 +/- 9.4 in the AperFix group (p < 0.022). There was no significance between the two groups in terms of laxity testing and complication rates. In the early postoperative period, satisfactory and comparable clinical results were achieved with the AperFix system when compared with cross-pin fixation in arthroscopic anterior cruciate ligament reconstruction.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20812579     DOI: 10.1055/s-0030-1262904

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  3 in total

1.  No Difference in Outcomes Between Suspensory (Fixed-Loop Cortical Button) Versus Expandable Anteromedial Femoral Fixation in Anterior Cruciate Ligament Reconstruction With Autologous Hamstring Tendons: A Prospective, Randomized, Controlled Study in Male Patients.

Authors:  Andreas Panagopoulos; Dimitris Mylonas; Antonis Kouzelis; Petros Zampakis; Pantelis Kraniotis; John Lakoumentas; John Gliatis
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-06-24

2.  Outcome of transtibial AperFix system in anterior cruciate ligament injuries.

Authors:  Gökay Görmeli; C Ayşe Görmeli; Mustafa Karakaplan; M Fatih Korkmaz; Uğur Diliçıkık; Harika Gözükara
Journal:  Indian J Orthop       Date:  2015 Mar-Apr       Impact factor: 1.251

3.  Diagnostic Accuracy of Lever Sign Test in Acute, Chronic, and Postreconstructive ACL Injuries.

Authors:  Tahsin Gürpınar; Barış Polat; Ayşe Esin Polat; Engin Çarkçı; Yusuf Öztürkmen
Journal:  Biomed Res Int       Date:  2019-06-09       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.