Literature DB >> 20811970

Brief review: Airway rescue with insertion of laryngeal mask airway devices with patients in the prone position.

Amir Abrishami1, Paul Zilberman, Frances Chung.   

Abstract

PURPOSE: Unintentional extubation of the trachea while the anesthetized patient is in the prone position is a potentially life-threatening situation that is usually managed by turning the patient supine for emergent re-intubation. However, this approach may delay definitive airway management and lead to irreversible complications. This review evaluates the efficacy of insertion of a laryngeal mask airway device (LMAD) with the patient in the prone position as a rescue method in airway management for unintentional tracheal extubation. PRINCIPAL
FINDINGS: We searched MEDLINE and EMBASE databases in the English language for the period 1980 to October 2009 in order to identify observational studies and case reports describing insertion of the LMAD with the patient in the prone position. We found 12 such articles (n = 526 patients) consisting of four retrospective studies, one prospective cohort with a control group, one non-controlled prospective study, and six case reports. On the first attempt, the LMAD was inserted successfully in 87.5-100% of the patients involved in the included reports. On the second attempt, the LMAD was inserted successfully in all patients, with or without laryngoscopy. Ventilation was maintained successfully in the lungs of 83.3-100% of the patients involved in the reported articles. Following insertion of the LMAD with patients in the prone position, the most common complications reported were sore throat, bleeding, bradycardia, and laryngospasm.
CONCLUSIONS: Cumulative experience from published reports suggests the feasibility of placing the LMAD with the patient in the prone position in the elective setting; however, the evidence is lacking regarding the use of this method for emergency management of unintended tracheal extubation with the patient in the prone position.

Entities:  

Mesh:

Year:  2010        PMID: 20811970     DOI: 10.1007/s12630-010-9378-1

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  6 in total

Review 1.  ERCP: the unresolved question of endotracheal intubation.

Authors:  Basavana Goudra; Preet Mohinder Singh
Journal:  Dig Dis Sci       Date:  2013-11-13       Impact factor: 3.199

2.  Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positions.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Akari Fujii; Aoi Samma; Masashi Nakagawa; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-04-12       Impact factor: 2.078

3.  Unintentional tracheal extubation during prone position: What is the best rescue airway device?

Authors:  Germano De Cosmo; Elisabetta Congedo
Journal:  J Emerg Trauma Shock       Date:  2017 Jan-Mar

4.  Supraglottic airway device versus a channeled or non-channeled blade-type videolaryngoscope for accidental extubation in the prone position: A randomized crossover manikin study.

Authors:  Hiroyuki Oshika; Yukihide Koyama; Masataka Taguri; Koichi Maruyama; Go Hirabayashi; Shoko Merrit Yamada; Masashi Kohno; Tomio Andoh
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

5.  Effect of head rotation on cerebral blood velocity in the prone position.

Authors:  Jakob Højlund; Marie Sandmand; Morten Sonne; Teit Mantoni; Henrik L Jørgensen; Bo Belhage; Johannes J van Lieshout; Frank C Pott
Journal:  Anesthesiol Res Pract       Date:  2012-09-05

6.  Intubation in prone position using AirTraq Avant videolaryngoscope.

Authors:  Tomasz Gaszynski
Journal:  J Clin Monit Comput       Date:  2018-03-19       Impact factor: 2.502

  6 in total