Literature DB >> 20810270

Biochemical gas sensor (bio-sniffer) for ultrahigh-sensitive gaseous formaldehyde monitoring.

Hiroyuki Kudo1, Yuki Suzuki, Tomoko Gessei, Daishi Takahashi, Takahiro Arakawa, Kohji Mitsubayashi.   

Abstract

An ultrahigh-sensitive fiber-optic biochemical gas sensor (bio-sniffer) for continuous monitoring of indoor formaldehyde was constructed and tested. The bio-sniffer measures gaseous formaldehyde as fluorescence of nicotinamide adenine dinucleotide (NADH), which is the product of formaldehyde dehydrogenase (FALDH) reaction. The bio-sniffer device was constructed by attaching a flow cell with a FALDH immobilized membrane onto a fiber-optic NADH measurement system. The NADH measurement system utilizes an ultraviolet-light emitting diode (UV-LED) with peak emission of 335 nm as an excitation light source. The excitation light was introduced to an optical fiber probe, and fluorescence emission of neighboring NADH, which was produced by applying formaldehyde vapor to the FALDH membrane, was concentrically measured with a photomultiplier tube. Assessment of the bio-sniffer was carried out using a standard gas generator. Response, calibration range and selectivity to other chemical substances were investigated. Circulating phosphate buffer, which contained NAD+, available for continuous monitoring of formaldehyde vapor. The calibration range of the bio-sniffer was 2.5 ppb to 10 ppm, which covers the guideline value of the World Health Organization (80 ppb). High selectivity to other gaseous substances due to specific activity of FALDH was also confirmed. Considering its high sensitivity, a possible application of the bio-sniffer is continuous indoor formaldehyde monitoring to provide healthy residential atmosphere.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20810270     DOI: 10.1016/j.bios.2010.07.099

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Pyrenyl carbon nanostructures for ultrasensitive measurements of formaldehyde in urine.

Authors:  Gayan Premaratne; Sabrina Farias; Sadagopan Krishnan
Journal:  Anal Chim Acta       Date:  2017-03-27       Impact factor: 6.558

2.  Aero-Thermo-Dynamic Mass Analysis.

Authors:  Kota Shiba; Genki Yoshikawa
Journal:  Sci Rep       Date:  2016-07-14       Impact factor: 4.379

Review 3.  High-Tech and Nature-Made Nanocomposites and Their Applications in the Field of Sensors and Biosensors for Gas Detection.

Authors:  Daniele Zappi; Matiss Martins Ramma; Viviana Scognamiglio; Amina Antonacci; Gabriele Varani; Maria Teresa Giardi
Journal:  Biosensors (Basel)       Date:  2020-11-13
  3 in total