Literature DB >> 20810243

Global longitudinal strain as a major predictor of cardiac events in patients with depressed left ventricular function: a multicenter study.

Aude Mignot1, Erwan Donal, Amira Zaroui, Patricia Reant, Adrien Salem, Cecile Hamon, Severine Monzy, Raymond Roudaut, Gilbert Habib, Stéphane Lafitte.   

Abstract

BACKGROUND: The risk stratification of patients with left ventricular (LV) dysfunction can be performed using echocardiographic parameters such as the ejection fraction (EF). Recently, new technologies based on deformation measurements have been shown to identify early myocardial dysfunction before EF decrease. Consequently, tools such as two-dimensional strain have been incorporated into echocardiographic systems, allowing for fast, reliable, and reproducible calculation of longitudinal components of LV systolic deformation. The hypothesis in this study was that as a more sensitive marker of LV dysfunction, longitudinal strain would allow for the risk stratification of patients with heart failure.
METHODS: This multicenter study included 147 patients with heart failure with LV EFs ≤ 45% (mean age, 64 ± 14 years; 74% men; mean LV EF, 29.9 ± 8.9%). Conventional echocardiographic parameters as well as global and segmental longitudinal strain were measured and compared with these values in a control population. Patients were monitored for cardiac events, defined as a composite criterion, over 12 months.
RESULTS: Clinical events were observed in 20% of patients during the 12-month follow-up period. On receiver operating characteristic curve analysis, global longitudinal strain had the highest prognostic value (area under the curve, 0.83) and the highest combination of sensitivity (73%) and specificity (83%), using a cutoff value of -7%.
CONCLUSION: Strain assessment is highly feasible and reliable in patients with LV dysfunction and allows for cardiovascular risk stratification in patients with heart failure with greater accuracy than LV EF.
Copyright © 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20810243     DOI: 10.1016/j.echo.2010.07.019

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  59 in total

1.  Inter-vendor reproducibility and accuracy of segmental left ventricular strain measurements using CMR feature tracking.

Authors:  Monica Dobrovie; Manuel Barreiro-Pérez; Davide Curione; Rolf Symons; Piet Claus; Jens-Uwe Voigt; Jan Bogaert
Journal:  Eur Radiol       Date:  2019-07-11       Impact factor: 5.315

2.  Relationship of left ventricular global longitudinal strain with cardiac autonomic denervation as assessed by 123I-mIBG scintigraphy in patients with heart failure with reduced ejection fraction submitted to cardiac resynchronization therapy : Assessment of cardiac autonomic denervation by GLS in patients with heart failure with reduced ejection fraction submitted to CRT.

Authors:  Madalena Coutinho Cruz; Ana Abreu; Guilherme Portugal; Helena Santa-Clara; Pedro S Cunha; Mario M Oliveira; Vanessa Santos; Luís Oliveira; Pedro Rio; Inês Rodrigues; Luís A Morais; Rui C Ferreira; Miguel M Carmo
Journal:  J Nucl Cardiol       Date:  2017-12-05       Impact factor: 5.952

3.  Comprehensive echocardiographic assessment of biventricular function in the rabbit, animal model in cardiovascular research: feasibility and normal values.

Authors:  Sara Roldan Ramos; Guido Pieles; Wei Hui; Ryo Ishii; Cameron Slorach; Mark K Friedberg
Journal:  Int J Cardiovasc Imaging       Date:  2017-08-24       Impact factor: 2.357

4.  Influence of chest conformation on myocardial strain parameters in healthy subjects with mitral valve prolapse.

Authors:  Andrea Sonaglioni; Gian Luigi Nicolosi; Michele Lombardo; Gian Franco Gensini; Giuseppe Ambrosio
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-30       Impact factor: 2.357

5.  Left ventricular global longitudinal strain predicts mortality and heart failure admissions in African American patients.

Authors:  Mayank M Kansal; Ibrahim N Mansour; Sahar Ismail; Adam Bress; Grace Wu; Omer Mirza; Rahul Marpadga; Hana Gheith; Yoonsang Kim; Yien Li; Larisa Cavallari; Thomas D Stamos
Journal:  Clin Cardiol       Date:  2017-03-08       Impact factor: 2.882

6.  Longitudinal assessment of myocardial function in childhood chronic kidney disease, during dialysis, and following kidney transplantation.

Authors:  Rawan K Rumman; Ronand Ramroop; Rahul Chanchlani; Mikaeel Ghany; Diane Hebert; Elizabeth A Harvey; Rulan S Parekh; Luc Mertens; Michael Grattan
Journal:  Pediatr Nephrol       Date:  2017-03-08       Impact factor: 3.714

Review 7.  Perioperative assessment of myocardial deformation.

Authors:  Andra E Duncan; Andrej Alfirevic; Daniel I Sessler; Zoran B Popovic; James D Thomas
Journal:  Anesth Analg       Date:  2014-03       Impact factor: 5.108

8.  Strain Assessment of Myocardial Function: A Better Approach or Just Fun and Games?

Authors:  Andra E Duncan
Journal:  Anesth Analg       Date:  2015-12       Impact factor: 5.108

9.  Early detection of cardiac dysfunction in the type 1 diabetic heart using speckle-tracking based strain imaging.

Authors:  Danielle L Shepherd; Cody E Nichols; Tara L Croston; Sarah L McLaughlin; Ashley B Petrone; Sara E Lewis; Dharendra Thapa; Dustin M Long; Gregory M Dick; John M Hollander
Journal:  J Mol Cell Cardiol       Date:  2015-12-03       Impact factor: 5.000

10.  Association of left ventricular longitudinal strain with mortality among stable hemodialysis patients with preserved left ventricular ejection fraction.

Authors:  Yen-Wen Liu; Chi-Ting Su; Junne-Ming Sung; Saprina P H Wang; Yu-Ru Su; Chun-Shin Yang; Liang-Miin Tsai; Jyh-Hong Chen; Wei-Chuan Tsai
Journal:  Clin J Am Soc Nephrol       Date:  2013-05-23       Impact factor: 8.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.