Literature DB >> 20808010

Proximal femoral medullary canal diameters in Indians: correlation between anatomic, radiographic, and computed tomographic measurements.

Ramesh Kumar Sen1, Sujit Kumar Tripathy, Raj Kumar, Amit Kumar, Sarvdeep Dhatt, Mandeep Singh Dhillon, O N Nagi, Madhu Gulati.   

Abstract

PURPOSE: To compare anatomic, radiographic, and computed tomographic (CT) measurements of the proximal femur in an Indian population.
METHODS: 26 left and 24 right dried cadaveric femurs were obtained. Each femur was divided into segments at 10 cross-sectional levels from proximal to distal. At each level, anteroposterior (AP), lateral, 45-degree internal oblique, and 45-degree external oblique diameters of the medullary canal were measured using radiography and CT. To minimise magnification, the femur was placed over the film/board. The neck shaft angle, femoral head offset, neck length, and femoral head diameter were also measured. For anatomic measurements, the cross-sections of the medullary canal at levels 3 to 10 were measured using a calliper. Anatomic measurements were compared with radiographic and CT measurements, and the distortion calculated. Correlation between the 3 modalities was calculated using the Pearson correlation coefficient. Accuracy index of the 2 diagnostic modalities was measured, based on the differences between anatomic and radiographic/CT measurements. Lower accuracy indices indicated higher accuracy.
RESULTS: On AP radiographs of all femurs, the mean femoral head diameter was 45 mm, the mean neck shaft angle was 132 degrees, the mean femoral head offset was 42 mm, and the mean neck length was 63 mm. With regard to medullary canal diameters, the radiographic and CT measurements were smaller than anatomic measurements at proximal levels, but similar at distal levels. Variations between femurs and between the 4 diameters at the same level were greater at proximal levels.
CONCLUSIONS: Combined use of radiography and CT is recommended for preoperative assessment of implant size, particularly in uncemented arthroplasty where an optimal fit is essential for biological fixation.

Mesh:

Year:  2010        PMID: 20808010     DOI: 10.1177/230949901001800211

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  5 in total

1.  The validity and reliability of preoperative radiographic canal diameter measurements of the femur.

Authors:  Kenneth P Walsh; John R Fowler; Oliver Chen; John P Gaughan; Sayed Ali; Mahin Rehman; Saqib Rehman
Journal:  HSS J       Date:  2013-06-21

2.  A Simple and Easy Intramedullary Lavage Method to Prevent Embolism During and After Reamed Long Bone Nailing.

Authors:  M N Baig; W Curtin
Journal:  Cureus       Date:  2017-08-25

3.  Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis.

Authors:  Mohd Yusof Baharuddin; Sh-Hussain Salleh; Ahmad Hafiz Zulkifly; Muhammad Hisyam Lee; Alias Mohd Noor; Arief Ruhullah A Harris; Norazman Abdul Majid; Ab Saman Abd Kader
Journal:  BMC Musculoskelet Disord       Date:  2014-02-03       Impact factor: 2.362

4.  Morphological study of the newly designed cementless femoral stem.

Authors:  Mohd Yusof Baharuddin; Sh-Hussain Salleh; Ahmad Hafiz Zulkifly; Muhammad Hisyam Lee; Alias Mohd Noor
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

5.  The best location for proximal locking screw for femur interlocking nailing: A biomechanical study.

Authors:  Ahmet A Karaarslan; Ahmet Karakaşli; Hakan Aycan; Berivan Çeçen; Didem Venüs Yildiz; Erhan Sesli
Journal:  Indian J Orthop       Date:  2016 Jan-Feb       Impact factor: 1.251

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.