Literature DB >> 20805775

Airway scope laryngoscopy under manual inline stabilization and cervical collar immobilization: a crossover in vivo cinefluoroscopic study.

Yoshihiro Aoi1, Gaku Inagawa, Kozo Hashimoto, Hideo Tashima, Sayaka Tsuboi, Takeshi Takahata, Kyota Nakamura, Takahisa Goto.   

Abstract

BACKGROUND: Direct laryngoscopy along with manual inline stabilization (MIS) is currently the standard care for patients with suspected neck injuries. However, cervical collar immobilization is more commonly performed in the prehospital environment, and its early removal is necessary before intubation. We hypothesized that if usability of Airway Scope (AWS) in a difficult airway could also bring merits to intubation under cervical collar immobilization, unnecessary risk caused by the removal of a neck collar may be prevented.
METHODS: In this crossover study, 30 consenting patients presenting for surgery were assigned to undergo intubation using AWS. Neck was stabilized manually and by a neck collar in a random order before laryngoscopy was performed by the same anesthesiologist. Measurements include interincisor distance (IID), success rate, intubation time, and fluoroscopic examination of the upper and middle cervical spine.
RESULTS: IID was notably narrower after application of a neck collar (mean ± SE: MIS, 19 mm ± 1 mm; collar, 10 mm ± 1 mm; p < 0.01). One and 9 failures were encountered in MIS and collar groups, respectively (p = 0.012). Intubation time proved no statistical significance. Extension of craniocervical junction was observed in both groups, but occipitoatlantal joint was significantly more extended in collar group (median [range]: AWS, 10-degree angle [-1 to 20-degree angle]; collar, 14-degree angle [5 to 26-degree angle]; p < 0.01). DISCUSSION: AWS laryngoscopy under cervical collar immobilization fails to meet our expectation. Intubation failed in 30% of the cases in collar group whereas only 3.3% of the cases in MIS group. Significant difference of mouth opening limitation is probably the major reason, as 7 of 9 failed cases in collar group had IID <10 mm. This was insufficient to insert the 18-mm blade of AWS. In addition, occipitoatlantal joint suffered a greater extension when wearing a neck collar. Differences in the method to stabilize the neck may be the reason.
CONCLUSION: When compared with cervical collar immobilization, AWS laryngoscopy along with MIS seems to be a safer and more definite method to secure airway of neck-injured trauma patients because it limits less mouth opening and upper cervical spine movement.

Entities:  

Mesh:

Year:  2011        PMID: 20805775     DOI: 10.1097/TA.0b013e3181e75873

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  7 in total

1.  A comparison of video laryngoscopy to direct laryngoscopy for the emergency intubation of trauma patients.

Authors:  Maria Michailidou; Terence O'Keeffe; Jarrod M Mosier; Randall S Friese; Bellal Joseph; Peter Rhee; John C Sakles
Journal:  World J Surg       Date:  2015-03       Impact factor: 3.352

2.  Anesthetic considerations in acute spinal cord trauma.

Authors:  Neil Dooney; Armagan Dagal
Journal:  Int J Crit Illn Inj Sci       Date:  2011-01

3.  Efficacy of Pentax airway scope versus Macintosh laryngoscope when used by novice personnel: A prospective randomized controlled study.

Authors:  Kyu Nam Kim; Mi Ae Jeong; You Na Oh; Soo Yeon Kim; Ji Yoon Kim
Journal:  J Int Med Res       Date:  2017-08-23       Impact factor: 1.671

4.  Effect of rigid cervical collar on tracheal intubation using Airtraq(®).

Authors:  Padmaja Durga; Chiranjeevi Yendrapati; Geeta Kaniti; Narmada Padhy; Kiran Kumar Anne; Gopinath Ramachandran
Journal:  Indian J Anaesth       Date:  2014-07

5.  Effect of 5 different cervical collars on optic nerve sheath diameter: A randomized crossover trial.

Authors:  Michal Ladny; Jacek Smereka; Sanchit Ahuja; Lukasz Szarpak; Kurt Ruetzler; Jerzy Robert Ladny
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817

6.  C-arm fluoroscopy for tracheal intubation in a patient with severe cervical spine pathology.

Authors:  Yukihide Koyama; Koichi Tsuzaki; Kazuo Ohmori; Koichiro Ono; Takeshi Suzuki
Journal:  Saudi J Anaesth       Date:  2020-05-30

7.  Two head positions for orotracheal intubation with the trachway videolight intubating stylet with manual in-line stabilization: A randomized controlled trial.

Authors:  Wei-Hung Chan; Chiao-Pei Cheng; Yu-Lung Chiu; Yung-Chi Hsu; Mei-Hua Hu; Go-Shine Huang