Literature DB >> 20802603

X-ray focusing using microchannel plates.

P Kaaret, P Geissbühler, A Chen, E Glavinas.   

Abstract

We present measurements of the x-ray focusing properties of square-pore microchannel plates (MCP's). Square-pore MCP's contain large numbers of closely packed optical surfaces, as required for grazing incidence x-ray optics. The surface of individual MCP channels has been measured and found to have high microroughness transverse to the channel axis and low microroughness parallel to the axis. The high frequency transverse roughness, on length scales greater than 400 nm, has a rms value of 5.9 nm and a Gaussian autocorrelation function with correlation length of 1.41 microm. We find that the geometric misalignments of the surfaces of different channels limit the angular resolution obtainable with current samples of MCP's to 7.1 arcmin.

Entities:  

Year:  1992        PMID: 20802603     DOI: 10.1364/AO.31.007339

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  1 in total

1.  Synchrotron radiation transmission by two coupled flat microchannel plates: new opportunities to control the focal spot characteristics.

Authors:  M I Mazuritskiy; A M Lerer; A Marcelli; S B Dabagov
Journal:  J Synchrotron Radiat       Date:  2022-01-19       Impact factor: 2.616

  1 in total