Literature DB >> 20801343

Determination of phenylurea and triazine herbicides in milk by microwave assisted ionic liquid microextraction high-performance liquid chromatography.

Shiqian Gao1, Jingyan You, Xia Zheng, Ying Wang, Ruibing Ren, Rui Zhang, Yuping Bai, Hanqi Zhang.   

Abstract

The determination of phenylurea and triazine herbicides in milk based on microwave assisted ionic liquid microextraction (MAILME) coupled with high-performance liquid chromatographic separation was described. The experimental parameters of the MAILE, including type and amount of ionic liquid, microwave extraction power, extraction time and salt concentration in sample, were evaluated by a univariate method and orthogonal screening. When 60 microL of [C(6)MIM][PF(6)] was used as extraction solvent the target compounds can be isolated from the 4 mL of milk. The MAILME is quick (7 min) and simple. The detection limits for isoproturon, monolinuron, linuron, propazine, prometryne, terbutryn and trietazine are 0.46, 0.78, 1.00, 1.21, 1.96, 0.84 and 1.28 microg L(-1), respectively. The proposed method was applied to the analysis of milk samples and the recoveries of the analytes ranged from 88.4 to 117.9% and relative standard deviations were lower than 7.43%. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20801343     DOI: 10.1016/j.talanta.2010.07.002

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  p-Phenylenediamine-modified graphene oxide as a sorbent for solid-phase extraction of phenylurea herbicides, nitroimidazoles, chlorophenols, phenylurea insecticides and phthalates.

Authors:  Liying Guo; Lin Hao; Tian Gao; Chun Wang; Qiuhua Wu; Zhi Wang
Journal:  Mikrochim Acta       Date:  2019-06-22       Impact factor: 5.833

2.  Analytical method validation for terbutryn using gas chromatography/ion trap, gas chromatography/mass selective detector, and liquid chromatography/triple quadrupole mass spectrometers.

Authors:  Hae Won Jang; Jangho Lee; Hyunwook Choi; Tae Gyu Nam; Seung-Hyun Kim; Kwang-Geun Lee
Journal:  Food Sci Biotechnol       Date:  2018-03-19       Impact factor: 2.391

3.  Molecularly Imprinted Dispersive Solid-Phase Extraction for the Determination of Triazine Herbicides in Grape Seeds by High-Performance Liquid Chromatography.

Authors:  Xinpei Li; Yuanpeng Wang; Qun Sun; Bo Xu; Zhaoqing Yang; Xinghua Wang
Journal:  J Chromatogr Sci       Date:  2016-03-23       Impact factor: 1.618

4.  Determination of carcinogenic herbicides in milk samples using green non-ionic silicone surfactant of cloud point extraction and spectrophotometry.

Authors:  N I Mohd; N N M Zain; M Raoov; S Mohamad
Journal:  R Soc Open Sci       Date:  2018-04-11       Impact factor: 2.963

5.  A Low-Cost Layered Double Hydroxide (LDH) Based Amperometric Sensor for the Detection of Isoproturon in Water Using Carbon Paste Modified Electrode.

Authors:  Herve Leclerc Tcheumi; Aude Peggy Kameni Wendji; Ignas Kenfack Tonle; Emmanuel Ngameni
Journal:  J Anal Methods Chem       Date:  2020-08-20       Impact factor: 2.193

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.